31

6. Notes on Operation

[1]

[2]

[3]

(2) Home

return

When performing a home-return operation to the rotary, the rotary direction to home-return differs as
shown in the figures below due to the position where the shaft is when the home-return operation
starts.

1) If the shaft does not detect the sensor at the home-return start, it moves counterclockwise in the

view of the shaft tip ([1]), and it reverses if sensor is detected ([2]), and then stops when the Z-
phase is detected. (Refer to Figure 1.)

Figure 1

2) If the shaft detects the sensor at the home-return start (when the shaft is rotated over 300

degrees by hand at the servo off), it rotates clockwise from the stopped position ([3]), and stops
when the Z-phase is detected. (Refer to Figure 2.)

Figure 2

Operation range of the rotary is generally 300 degrees. However, in some cases it rotates 360
degrees as stated above.
Be careful of interference of the rotary to its surroundings.

Operation range (300 degrees)

Sensor detection range

Sensor sensitive device

Home

Shaft

C

Operation range (300 degrees)

Sensor detection range

Sensor sensitive device

Home

Shaft

Advertising