3. XSEL-R/S/RX/SX/RXD/SXD

27

3.6 Connection to Network

EtherNet/IP occupies EtherNet Port No.44818 and 2222.

The connection of EtherNet/IP is established by indicating the port 44818 in the IP address of

XSEL Controllers in EtherNet/IP software.

Caution Please note that Port No.2222 (UDP Port) and 44818 (TCP Port and UDP Port)

must be open for use by any firewall configuration.

Caution In case EtherNet/IP Remote IO Communication and TCP/IP Message

Communication are being used at the same time, the reset command from the

network configurator may not be executed properly.

If an execution of the reset from the configurator is required, temporarily

inactivate TCP/IP Message Communication (by setting 0 to I/O Parameter No.

129 ̌Network Attribute 10̍), and conduct the reset. (Make sure to put back the

setting after reset is done.)

3.7 Standard I/O Ports of XSEL Controller

It is available to add special functions beside the general-purposed input and output in the

standard I/O ports of XSEL Controllers.
=

Refer to XSEL-R/S/RX/SX/RXD/SXD Controller Operation Manual for the details.?

[Settings of Standard I/O Ports at Delivery]












(Note) Number of standard I/O ports is:

Input 000 to 299 (300 points max.)

Output 300 to 599 (300 points max.)

Be careful of the number of I/O ports when using EtherNet/IP and PIO together.

Input Port

Output Port

Port

No.

Function

Port

No.

Function

000

Program Start

300

Alarm Output

001

Universal Input

301

Ready Output

002

Universal Input

302

Emergency Stop Output

003

Universal Input

303

Universal Output

004

Universal Input

304

Universal Output

005

Universal Input

305

Universal Output

006

Universal Input

306

Universal Output

007

Program Specification

(LSB)

307

Universal Output

008

Program Specification

308

Universal Output

009

Program Specification

309

Universal Output

010

Program Specification

310

Universal Output

011

Program Specification

Indicate startup

program

number with in

binary

311

Universal Output

012

Program Specification

312

Universal Output

013

Program Specification

(MSB)

313

Universal Output

014

Universal Input

314

Universal Output

015

Universal Input

315

Universal Output

• •

• •

Advertising