IAI America RCB-ISL-SIO User Manual

Page 2

Advertising
background image

+24V

0V

Personal Computer

SIO Isolator

Terminal Resistance

SIO connector

24V

Power-

supply

Required Cables

USB Cable CB-SEL-USB

USB Conversion Adaptor RCB-CV-USB

(attachment to the PC application software RCB-CV-USB)

Isolator Communication Cable CB-RCB-SIO

□□□

External Machine Communication Cable CB-RCA-SIO

□□□

+24V

0V

+24V

+24V

0V

0V

+24V

0V

Master Unit

Gateway unit

Made by the client

SIO Isolator

SIO Isolator

Isolator Link Cable

External machine

communication

cable

Terminal Resistor

24V Power-

supply

PS1

24V Power-

supply

PS2

24V Power-

supply

PS4

24V Power-

supply

PS3

Controller

Controller

e-Con

Connector

Single-phase

(In case of SCON)

(3)

Connection Example 3:

In the case of the link connection through the gateway unit:

In the case that the 0V line for the power to each controller can not be shared, or the
DC24V type controllers are used together with the AC100/200V controllers, the power
source can be separated for each controller as shown in the figure.




























Because the power to the primary circuit inside the SIO isolator is supplied from CN1, make
sure to connect CN1.

(4)

Connection Example 4: In the case that the PC is connected while the positive side of the

24V power is grounded:

Inside the most PCs, the GND (0V) line for the communication is short-circuited to FG
(frame ground), when the PC is connected, a short-circuit occurs in the 24V power line
which might cause the PC breakdown. In such case, connect the controller (including the
gateway and ROBONET) using the SIO isolator and USB conversion adaptor
(RCB-CV-USB) as shown in the figure.






















1. The RS232C conversion unit RCB-CV-MW (attachment to the PC application software

RCM-101-MW) can not be used for the connection between the PC and SIO isolator.

2. Connect the external machine communication cable (3) to CN1 for the SIO isolator.




CAUTION

CAUTION

Advertising