35mmdin rail end plate – IAI America RCB-ISL-SIO User Manual

Page 3

Advertising
background image

35mmDIN rail

End plate

Slider

Lower the slider to the lowermost position.

Pull down the pin.

Hook the DIN rail on the claw.

Rear side of
the RC-SIO isolator

Front side of the RC-SIO isolator.

End plate

Connect the adjacent isolators
using the isolator link cable
(CB-ISL-SIO

□□□

).

Connect the isolator with
the each axis controller using
the external machine communication
cable(CB-RCA-SIO

□□□

).

Insertion Port for
Communication Cable
on the Host Side.

Attach the attached terminal
resistance at the end of
the isolator link.

SGA

SGB

GND

1
2
3
4
5
6

BR

RD

-

GND

5V

5V

YW

OR

BL
GR

Color Signal

No.

(Cable Length 2m)

(Cable Length 5m)

YW

OR

BK

Color

Signal

No.

SGA

SGB

GND

1
2

3
4

BR / GR

RD / BL

5V

5
6

7

8

EMCS

EMCA

24V

EMGB

-

-

BK

Shield

FG

Short-Circuit Cable

ޓUL1007AWG2B(Black)

Shield Unconnected

No.

SGB

FG

1
2
3
4

WT

GND

SGA

Signal Color

YW

WT

BL

CN2

4-1473562-4

No.

SGB

FG

1
2
3
4

WT

GND

SGA

Signal

Color

YW

WT

BL

CN1

4-1473562-4

□□□

indicates the cable length L

e-Con connector
(Green)

e-Con connector
(Green)

Shrink Tube(Black)

7. Attachment and Wiring

(1) Procedure

① Because the RC-SIO isolator is attached onto the DIN rail, prepare the

following 35mm DIN rail and end plate.

















② Lower the slider to the lowermost position on the rear side of the RC-SIO

isolator.





















③ There is the DIN rail attachment section on the slider on the rear side of the

isolator. Hook the DIN rail on the upper claw in the attachment section as
shown in the picture and set the isolator onto the rail with the pin (spring type)
on the lower position on the attachment section pulled down. Then, finally,
release the pin to lock the isolator.




















④ Using the same procedure, attach the required number of isolators onto the

DIN rail.



















⑤ Fix the both ends of the attached RC-SIO isolators using the end plates.


















⑥ Connect the cables.

















⑦ Insert the terminal resistance.















(2) List of the Cables to be used

① Isolator Communication Cable CB-RCB-SIO□□□




















② Isolator Link Cable CB-ISL-SIO□□□






















③ External Machine Communication Cable CB-RCA-SIO□□□






















No.

SGA

SGB
GND

1
2
3
4
5
6

-

-

-

GND

5V

5V

Signal Color

YW

OR

BL

No.

SGB

FG

1
2
3
4

-

GND

SGA

Signal Color

BL

OR

YW

□□□

indicates the cable length L

CN1

NTC-66R

CN2

3-1473562-4

e-Con connector
(Orange)

Shrink Tube(Black)

Advertising