Iai america inc, Iai industrieroboter gmbh – IAI America RCB-ISL-SIO User Manual

Page 4

Advertising
background image

Host PLC
Gateway Unit etc.

Double Shield Cable
Recommend : TAIYO ELECTRIC WIRE & CABLE
HK-SB/20276×L
2P×AWG22

e-Con connector
(Made of AMP 4-1473562-4 : Green)

SIO Isolator

e-Con connector

Pressure-weld

Vinyl cable
(AWG22)

Weld

Shield cable

Cable tube

Double shield cable

Locking claw

Pin No. of e-Con Connector

Wire Connection Port

Locking claw

(3) Pressure Welding Method for the e-Con Connector for the Client-made Cable

(RS485 Communication Line)





































For the connection to the e-Con connector, use the cable with the same core-wire size (equivalent to
AWG22) without peeling off the jacket of that core wires. If the jacket is peeled off, short-circuit might
be caused due to a connection error.

IAI America Inc.

Head Office: 2690W 237th Street Torrance, CA 90505

TEL (310) 891-6015 FAX (310) 891-0815

Chicago Office: 1261 Hamilton Parkway Itasca, IL 60143

TEL (630) 467-9900 FAX (630) 467-9912

Atlanta Office: 1220-E Kennestone Circle,Marrietta,GA 30066

TEL (678) 354-9470 FAX (678) 354-9471

website: www.intelligentactuator.com

IAI Industrieroboter GmbH

Ober der Röth 4, D-65824 Schwalbach am Taunus, Germany

TEL 06196-88950 FAX 06196-889524

Use the following procedure for the connection to the
attached e-Con connector.
①Peel off the jacket 15 to 20 mm from the

double shield cable.

②Twist the shield wires and weld them onto the

vinyl cable equivalent to AWG22.

③Cover it with the cable protection tube

(perform the terminal treatment using the
shrink tube).

④Without peeling off the core jacket, insert four

core wires into the connector cable insertion
holes (SDA, SDB, GND, FG).

⑤Keeping the core wires in the holes,

pressure-weld the cable press-fitting housing
from above.