3.1 STANDARD FEATURES

Model KBWA-23D: Housed in a NEMA 1 / IP20 vented enclosure.

Models KBWA-22D, 21D, 2P6D, 2P3D: Housed in a NEMA 1 / IP50 non vented

enclosure.

Dual Voltage AC Line Input Operation: The drive operates from 115 and 208/230

Volt 50/60 Hz AC Line input. See Section 7.1, on page 19.

Simple to Operate: Does not require programming. Uses trimpots and jumpers,

which are factory set for most applications.

Factory Installed On/Off AC Line Switch: The switch illuminates when power is

applied to the drive and the switch is in the on position.

Factory Installed Main Speed Potentiometer: Provides adjustment of motor

speed.

Diagnostic LEDs: Power on (PWR) and drive status (ST). See Sections 14.2 and

14.3, on page 34.

Jumper Selection for Drive Output Frequency (Jumpers J1 and J2): Increases

motor speed up to two times the rated RPM. See Section 7.2, on pages 19 – 21.

Jumper Selection for Automatic and Manual Start (CON1): With the jumper

installed, the drive will automatically start after a fault has been cleared. With the
jumper removed, the drive must be manually restarted, after a fault has been
cleared. The supplied Forward-Stop-Reverse Switch must be installed for Manual
Start Operation. See Section 7.3, on pages 21 and 22.

Jumper Selection for Motor Direction (CON2): Allows selection of Forward or

Reverse

direction.

See

Section

7.4,

on

page

22.

The

supplied

Forward-Stop-Reverse Switch can be installed to provide motor reversing and stop,
as described in Section 6, on pages 16 and 17.

Forward-Stop-Reverse Switch (Supplied): Easily Installs in the drive. See Section

6, on page 18.



3.2 PERFORMACE

FEATURES

Power Start™: Provides more than 200% starting torque which ensures startup of

high frictional loads.

Flux Vector Control with Static Auto-Tune: Provides excellent load regulation

over a wide speed range.

Speed Range: 60:1