FIGURE 16

TYPICAL HI-POT TEST SETUP




12 TRIMPOT

ADJUSTMENTS

The drive contains trimpots which are factory set for most applications. See Figure 2,
on page 8, for the location of the trimpots and their approximate factory calibrated
positions. Some applications may require readjustment of the trimpots in order to tailor
the drive for a specific requirement. The trimpots may be readjusted as follows.

WARNING! If possible, do not adjust trimpots with the main power

applied. If adjustments are made with the main power applied, an insulated
adjustment tool must be used and safety glasses must be worn. High voltage
exists in this drive. Fire and/or electrocution can result if caution is not
exercised. Safety Warning, on page 2, must be read and understood before
proceeding.