J1 Set for

208/230 Volt AC Line Input

(Factory Setting)

J1 Set for

115 Volt AC Line Input

J1

J1

7.2

Motor Voltage and DC Tach-Generator Selection –

Jumper J2 is factory set to the “90” position on Model

KBMM-125, for 90 Volt DC motors, and set to the

“180” position, on Models KBMM-225, 225D, for 180

Volt DC motors. To set Models KBMM-225, 225D for

step-down operation (208/230 Volt AC line input and

90 Volt DC output), set Jumper J2 to the “90” posi-

tion). To set the control for tach-generator connection,

set Jumper J2 to the “T” position (all models). See

Figure 12.

Notes: 1. On Model KBMM-125, the “180” position is not available on Jumper J2. 2. On Model KBMM-

225D, do not set the output voltage to 180 Volts DC when the AC line input is set to 115 Volts.

FIGURE 11 – AC LINE INPUT VOLTAGE SELECTION

(JUMPER J1) – MODEL KBMM-225D ONLY

8

AC LINE AND ARMATURE FUSING

All fuses should be normal blow ceramic 3AG, MDA, or equivalent. On domestic 230 Volt AC lines, separate

branch circuit protection for each line must be used. The optional Barrier Terminal Board (Part No. 9897) contains

prewired AC line and armature fuse holders, as described in Section 14.3, on page 30.

Model KBMM-125

Models KBMM-225 and KBMM-225D

J2 Set for

90 Volt Motor

(Factory Setting)

J2 Set for

Tach-Generator

J2 Set for

180 Volt Motor

(Factory Setting)

J2 Set for

90 Volt Motor *

J2 Set for

Tach-Generator

J2

J2

J2

J2

J2

FIGURE 12 – MOTOR VOLTAGE & DC TACH-GENERATOR SELECTION (JUMPER J2)

* Be sure jumper for 90 Volt DC output is installed in the two center pins, as shown.