F1 sw6 blu, A+ l1 l2 a- tb1 f2, Wht sw3 – KB Electronics KBWM-240 User Manual

Page 5: Line arm

Advertising
background image

3

3/4, (0.50)

Model No.

Part No.

Input Voltage

(VAC - 50/60 Hz)

9380

9381

KBWM-120

KBWM-240

Max. AC

Load Current

(RMS Amps)

Armature

Voltage (VDC)

Max. DC

Load Current

(DC Amps)

Max. Horsepower

HP, (kW)

1/3, (0.25)

115

208/230

5.0

5.0

5.0

0 – 90

0 – 180

0 – 90*

3.5

3.5

3.5

1/3, (0.25)

TABLE 2 – ELECTRICAL RATINGS

*Note – Step-down Operation: Motor may have reduced brush life. Consult motor manufacturer.

MAX

MIN

P2

P3

P1

I1

I2

ACCEL

DECEL

L1

T

L2

B

F+

F1

SW6

BLU

LINE

ARM

A+

L1

L2

A-

TB1

F2

IR

CL

F-

WHT

SW3

180V

90V

J2

ON KBWM-240 ONLY

J2 IS INSTALLED

PLUG-IN

HORSEPOWER RESISTOR

(CUSTOMER INSTALLED)

(FACTORY INSTALLED)

LINE FUSE

(CUSTOMER INSTALLED)

CL LED

SEE TABLE 4, PAGE 5

SEE TABLE 3, PAGE 5

ARMATURE FUSE

FIGURE 1 – CONTROL LAYOUT

(Illustrates Approximate Factory Setting of Trimpots and Jumper)

PLUG-IN HORSEPOWER RESISTOR
A Plug-in Horsepower Resistor® must be installed to match
the drive to the motor horsepower and armature current. See
Table 4, page 5 for the correct value. Plug-in Horsepower
Resistors® are stocked by your distributor.

CAUTION: Be
sure Plug-In
Horsepower
Resistor® is
inserted com-
pletely into
mating sockets.

Advertising
This manual is related to the following products: