Figure 5b – half voltage field – KB Electronics KBWM-240 User Manual

Page 9

Advertising
background image

Caution: If control is wired to a transformer, it is advisable to switch the secondary to dis-
connect power. If the primary is switched, additional snubber capacitors may have to be
added across terminals L1 and L2 to prevent power bridge damage.

Separate branch fusing or circuit breaker may be required on 208/230 VAC applications. (See
Section IV E, on page 8.)

B. Motor Armature – Wire the motor armature wires to terminals A+ and A-. Be sure the motor

voltage corresponds to the control voltage rating. See Figure 4, on page 6. Note: If motor
runs in opposite direction to what is required, turn power off and reverse armature leads.

WARNING!

Do not wire a switch or relay in series with the armature leads.

Armature switching can cause catastrophic failure of motor and/or control. If

reversing or dynamic braking is required, consult the Sales Department.

C. Ground (earth) – Be sure to ground motor and control to green ground stud located between

the Bx knockouts. See Figure 7, on page 11.

D. Field (Shunt motors only) – Do not use F+ and F- terminals for any other motor type. The

KBWM™ control is primarily designed for permanent magnet (PM) motors. However, a shunt
motor can also be controlled by wiring the shunt field directly to the 1/4” quick-disconnect ter-
minals located on the main speed control module. See Figures 5A and 5B for the F+ and F-
terminal locations. Attach motor field using insulated 1/4” Q-D female terminals. For
Standard PM (2-wire) motors, the Field is not used.

CAUTION: Shunt-wound motors may be damaged if field remains connected without motor
rotating for an extended period of time.

7

!

MIN

I1

I2

T

L2

B

F+

F1

SW6

BLU

LINE

ARM

A+

L1

L2

A-

TB1

F2

F-

WHT

SW3

AC LINE

MOTOR

M

FIELD*

-

+

-

+

180V

90V

J2

F+, L1

AC Line Voltage VAC

Motor Voltage

Field Voltage (Volts DC)

Field Connection

115

115

208/230

208/230

208/230

0 – 90

0 – 90

0 – 180

0 – 180

0 – 90

100

50

200

100

100

F+, F-

F+, L1

F+, F-

F+, L1

TABLE 6 – FIELD CONNECTION (Shunt Wound Motors Only)

FIGURE 5A – FULL VOLTAGE FIELD

MIN

I1

I2

T

L2

B

F+

F1

SW6

BLU

LINE

ARM

A+

L1

L2

A-

TB1

F2

F-

WHT

SW3

AC LINE

MOTOR

M

FIELD*

+

-

-

+

180V

90V

J2

FIGURE 5B – HALF VOLTAGE FIELD

*Shunt motors only

Advertising
This manual is related to the following products: