ADC Modem MM701G User Manual

Page 38

Advertising
background image

Managing DSL

32

MM701G User Manual

2

Configure the following parameters as supplied by your service provider:

3

Click

Apply,

then save changes using

“Saving Changes” on page 38

.

Parameter

Description

Exec Mode

Select CPE or CO. For point-to-point connections, one modem must
be configured for CPE and the other for CO. For all other applications,
select CPE.

Standard

Select Annex A or Annex B (Default: Annex A). Annex A and Annex B
are both transmission standards. Annex A is most often used in North
America. Annex B is most often used in Europe.

Startup Margin

Select a value from 2 DB to 15 DB. Applies only to Rate-Adaptive mode
(Default: 2 DB).

Power Backoff

Select Enable or Disable (Default: Enable).

Clock Offset

Do not change from factory-ship configuration.

Upstream Frame Sync Word

Do not change from factory-ship configuration.

Upstream Stuffbits

Do not change from factory-ship configuration.

Downstream Frame Sync Word

Do not change from factory-ship configuration.

Downstream Stuffbits

Do not change from factory-ship configuration.

Encoder Coefficient A

Do not change from factory-ship configuration.

Encoder Coefficient B

Do not change from factory-ship configuration.

Minimum Base Rate

Enter a value from 1 to 36 to select the minimum acceptable data rate
in Rate-Adaptive mode. Rate is equal to N*64kbps, where N is the
selected value (Default: 1).

Maximum Base Rate

Enter a value from 1 to 36 to select the maximum acceptable data rate
in Rate-Adaptive mode. Rate is equal to N*64kbps, where N is the
selected value (Default: 36).

Minimum Sub Rate

Enter 0 or 1 (Default: 0).

Maximum Sub Rate

Enter 0 or 1 (Default: 1).

Wire Pair Mode

Select Single or Two (Default: Single).

Asymmetric PSD

Select Disabled, 1544 kb, or 784 kb (Default: Disabled).

Bit Rate Mode

Select Adaptive Rate or Fixed Rate (Default: Adaptive Rate).

Test Bit Rate

Select a value from 72K to 2368K (Default: 2320K).

SNR Margin Limit

Enter a value from -64 to 63. Used to control the front panel LED.
(Default: 4).

Advertising