LEESON SM Series Quick Reference Guide User Manual

Sm series quick reference guide, Variable speed ac motor drives, Sm terminal strip diagnostic and display messages

Advertising
background image

Variable Speed AC Motor Drives

SM Series

Quick Reference Guide

7KLV JXLGH LV LQWHQGHG DV DQ DLG WR FRQILJXUH WKH 60 6HULHV GULYH

NOTE:

%HIRUH LQVWDOOLQJ DQG RSHUDWLQJ WKH 60 GULYH SOHDVH

UHDG DQG EHFRPH IDPLOLDU ZLWK WKH 60 6HULHV LQVWDOODWLRQ

DQG RSHUDWLRQ PDQXDO

6KRZQ EHORZ DUH WZR VDPSOH ZLULQJ GLDJUDPV LQFOXGLQJ

IRUZDUGUHYHUVH GLUHFWLRQ FRQWURO 2QH VKRZV D WKUHHZLUH

VWDUWVWRS FRQWURO XVLQJ PRPHQWDU\ FRQWDFWV DQG WKH RWKHU VKRZV D

ZLUH VWDUWVWRS FRQWURO XVLQJ PDLQWDLQHG FRQWDFWV 5HTXLUHG

SDUDPHWHU VHWWLQJV DUH DOVR LQFOXGHG

:,5( 67$576723
6HW 3DUDPHWHU  7%$

WR 6WDUW 5HYHUVH  

6HW 3DUDPHWHU  7%(

WR 6WDUW )RUZDUG  

6HW 3DUDPHWHU  5RWDWLRQ

WR )RUZDUG DQG 5HYHUVH  

SM TERMINAL STRIP

DIAGNOSTIC AND DISPLAY MESSAGES

BULLETIN #2454

3577S/1000/6-02/RL/BH

STOP

SIGNAL COMMON

0-10 VDC SPEED REFERENCE INPUT

SPEED POT POWER SUPPLY

DIGITAL INPUT REFERENCE

TB-13A FUNCTION SELECT

TB-13B FUNCTION SELECT

TB-13E FUNCTION SELECT

4-20 mA SPEED REFERENCE INPUT

DISPLAY

DESCRIPTION

Speed Reference Codes

CP

CONTROL PAD: The drive speed is controlled by the and

buttons on the front of the drive.

EI

EXTERNAL CURRENT: The drive speed is controlled by a 4-20 mA signal between TB-25 and TB-2

EU

EXTERNAL VOLTAGE: The drive speed is controlled by a 0-10 VDC signal between TB-5 and TB-2.

JG

JOG: The drive is in Jog mode and the speed is set by preset speed #2 (Parameter 32).

OP

MOP: Contacts wired to TB-13B and 13C are used to increase and decrease the drive speed.

Pr1-Pr7

PRESET SPEEDS #1-7: The drive speed is set by the selected Preset Speed (Parameters 31-37).

Status Indication

br

DC BRAKING: The DC braking circuit is activated.

CL

CURRENT LIMIT: The output current has exceeded the CURRENT LIMIT setting (Parameter 25)
and the drive is reducing the output frequency to reduce the output current. If the drive
remains in CURRENT LIMIT for too long, it can trip into a CURRENT OVERLOAD fault (PF).

Er

ERROR: Invalid data has been entered.

GE

“GE” will be displayed if an attempt is made to change the OEM default settings when the
drive is operating in the OEM mode (see Parameter 48).

LC

FAULT LOCKOUT: Failed three restart attempts. Requires a manual reset.

SE

SERIAL: The optional remote keypad is active as the user interface instead of the buttons on the
front of the drive.

SP

START PENDING: This is displayed during the 15 second interval between restart attempts.

Diagnostic Codes

AF

HIGH TEMPERATURE FAULT: Ambient temperature is too high.

CF

CONTROL FAULT: A blank EPM, or EPM with corrupted data has been installed. Perform a
factory reset (Parameter 48).

cF

INCOMPATIBILITY FAULT: An EPM with a different parameter version has been installed.

dF

DYNAMIC BRAKING FAULT: The drive has sensed the dynamic braking resistors are overheating.

EF

EXTERNAL FAULT: TB-13A and/or TB13C is set as an external fault input and TB-13A and/or
TB-13C is open with respect to TB-2.

GF

DATA FAULT: User data and OEM defaults in the EPM are corrupted.

HF

HIGH DC BUS VOLTAGE FAULT: Line voltage is too high; Deceleration rate is too fast;
Overhauling load. Fast deceleration and overhauling loads may require dynamic braking.

JF

REMOTE KEYPAD FAULT: The communication link between the drive and the optional Remote
Keypad has been lost. Check for proper wiring and/or noise.

LF

LOW DC BUS VOLTAGE FAULT: Line voltage is too low.

OF

OUTPUT TRANSISTOR FAULT: Phase to phase or phase to ground short circuit on the
output: Failed output transistor: Boost settings are too high: Acceleration rate is too fast.

PF

CURRENT OVERLOAD FAULT: VFD is undersized for the application: Mechanical problem with
the driven equipment.

SF

SINGLE-PHASE FAULT: Single-phase input power has been applied to a three-phase drive.

UF

START FAULT: Start command was present when the drive was powered up. Must wait
2 seconds after power-up to apply Start command if START METHOD is set to NORMAL.

F1

EPM FAULT: The EPM is missing or damaged.

FC,F2-Fo

INTERNAL FAULTS: The control board has sensed a problem. Consult factory.

:,5( 67$576723
6HW 3DUDPHWHU  7%$

WR 5XQ 5HYHUVH  

6HW 3DUDPHWHU  5RWDWLRQ

WR )RUZDUG DQG 5HYHUVH  

1

2

5

6

11

13A

13B

13E

25

16

17

PROGRAMMABLE FORM A RELAY

1

2

5

6

11 13A 13B 13E 25

Momentary

Momentary

Stop Contact

Start Contact

1

2

5

6

11 13A 13B 13E 25

Maintained

Maintained

Run Forward

Run Reverse

Contact

Contact

REV

FWD

A Subsidiary of REGAL-BELOIT CORPORATION