Erase

English

1. Use the play operation to display the picture you wish to

erase. (P21)

Push the SET button and REC button simultaneously for

2 sec. to erase.

2. The picture to be erased is deleted, and the next picture

will be displayed. When the next picture is displayed, let

go of the button.

1. Erase operations will also erase saved pictures.
2. Once a picture is erased, it cannot be restored.
3. It is not possible to delete only a single sub screen of a

4-frame picture recorded in 16-picture/4-frame mode.

4. To erase all of the pictures, change recording mode in

the settings. This will erase all of the pictures recorded

up to that point. (P11)

8

SURVEILLANCE SETTING

Prrrrrrrr

If a sensor light is installed (local product)

English

1. If something is detected by the sensor (locally available

product), an alarm goes off with a sound and a warning

screen. If more than 1 min. has passed after the absence

set (auto absence recording) was set, motion detection will

be in operation.

2. Press the TALK button to restore. (Automatic restoration

after approx. 30 sec.)

1. JB-2MED only.
2. Read the instruction manual for the sensor light (local

product), or contact your local installer or dealer.

NOTES: 1. In step 1, the length of time that the alarm

sounds can be changed. (P11)

2. Press the TALK button to stop the alarm and

warning screen.

3. Communication with the sensor light is not

possible.

4. If the absence set (auto absence recording) is

cancelled, the sensor light does not call the unit,

but the sensor light continues with its

surveillance function.

5. In calling and communication, sensored

alarming sound does not come out.

6. Also the alarming sound does not come out

through Sub room master station(s).

9

TECHNICAL PRECAUTIONS

Technical precautions

English

• Operating temperature: 0 °C to 40 °C (+32 °F to +104 °F)

• After the unit is not used for a long time or after an extended

power failure (approx. 30 min. or more), if both the PLAY

and REC buttons light at the same time, perform the record

function settings again. (P11)

• The video image may distort when the DOOR RELEASE

button is pressed. This is not a unit malfunction.

• Cleaning: Clean the units with a soft cloth dampened with a

neutral household cleanser. Do not use an abrasive cleaner

or cloth.

• The entrance station is weather-resistant. However, do not

spray it directly with high-pressure water. Unit trouble could

result.

• If there is a system malfunction, turn the power switch at the

master station off and back ON again. If this does not solve

the problem, unplug the DC power supply and contact a

qualified technician for service.

10

SPECIFICATIONS

Specifications

English

DC 18 V(JB-2MED, JB-2MD, JB-

2HD).

(Max.) 770mA (JB-2MED)

(Max.) 670 mA (JB-2MD)

(Max.) 250 mA (JB-2HD)

Chime and image, approx. 45

sec.

(AUTO) Handsfree, approx. 60

sec.

(MANUAL) Press to talk, release

to listen, approx. 60 sec.

3-1/2 " direct view TFT color LCD.

525 lines.

Door release contact: AC/DC 24

V, 0.5 A (dry closure contact L, L).

(Aiphone's EL-9S is

recommended.)

175(H) x 115(W) x 43(D) (mm).

6-7/8 " H x 4-7/32 " W x 1-11/16 "

D

Approx. 430 g (0.95 lbs.) (JB-

2MED)

Approx. 400 g (0.9 lbs.) (JB-2MD,

JB-2HD)

• Power:

• Current consumption:

• Calling:

• Communication:

• Video monitor:

• Scanning lines:

• Door release contact:

• Dimensions:

• Weight: