Multi-link triggering – Teledyne LeCroy SierraNet M168 User Manual Ver.1.40 User Manual

Page 141

Advertising
background image

    

SierraNet M168 User Manual

139

Advanced Mode (User‐Defined)

 Teledyne  LeCroy

Figure 2.90: Filter Settings Dialog

10. If you choose Capture Everything, you can select Idles for exclusion. 
11. Select Filter In Selected Patterns or Filter Out Selected Patterns to select patterns 

for inclusion or exclusion (see Figure 2.90). See 

“Ethernet Patterns (Easy Mode)” on 

page 65

.

12. Choose pattern(s) and click the > button to add them for capture or exclusion. You 

define each pattern the same way as in Easy mode (

“Ethernet Patterns (Easy Mode)” 

on page 65

).

13. Click Capture Nothing to run the trace without capturing anything.
14. Click on the checkboxes to Always Filter Out Idles or ports 1 through 8.
15. Select ARBFF, NOS, VC_RDY, Before ports are up, or Training Pattern. ARBff, NOS and 

VC_RDY are ordered sets that show up frequently and are of little use in most cases, 
and selecting allows you to specifically filter them out. Before ports are up will filter 
everything before the ports are up, to save buffer space and allow to concentrate on 
the parts important to the user. Training Pattern will similarly filter out all Training 
Patterns

16. Check the Truncate Payload option to truncate payload after x‐number of Dword(s) 

0 bytes. (see Figure 2.90). 

Multi-Link Triggering

You can set different triggering for each link. To set different trigger conditions for a link, 
check the Multi Sequencer checkbox and select the link for setup from the Port tabs. 
When you select this option, you can define a sequencer per link (pair port). These 
sequencers are independent from each other and will be run separately on each link. 

Advertising