Report between cursors – Teledyne LeCroy Sierra M124 User Manual User Manual
Page 130

Teledyne LeCroy
Analysis
128
Sierra M124 SAS/SATA Protocol Analyzer User Manual
Figure 3.23: Enabling Read/Write Statistical Report
Note:
This setting should be enabled before you capture the trace file.
If you have already captured a trace file and want to create a read/write statistical report
for the sample, perform the following steps:
1. Enable the read/write settings as mentioned above.
2. Open the trace file.
3. Set the X pointer on the first packet in the viewer.
4. Set the Y pointer on last packet in the viewer.
5. Save as the trace file using the X to Y option.
Now the saved trace file will contain the read/write statistical report.
Report Between Cursors
Click the option button next to the From cursor selection drop down list. Then click the
From down arrow and choose the 1st cursor, click the To down arrow to choose the 2nd
cursor, and click OK. The resulting report has only the capture between the cursors (see