D. configure serial data – Teledyne LeCroy Signal Integrity Studio User Manual
Page 10

Signal Integrity Studio
920134 RevA
10
D. Configure Serial Data
Select Serial Data... from the
Analysis menu to open Serial Data
Analysis II dialog:
1. Click the Enable SDA, Enable
Eye Meas. and Enable Jitter
Meas. checkboxes.
2. Click the Setup Signal Input
button to configure the signal
to analyze:
a. Select 1 Input (or Diff
Probe), and set Input 1 to
use the Eye Doctor output:
EDrOut.
3. Go to the Clock Recovery tab:
a. Enter the bit rate of the
simulated signal, or click
Find Rate.
4. Select the Eye Measure tab,
and click the checkboxes
Enable Eye Measure and Show Eye to display the eye diagram.
5. Select the Jitter Measure tab and click the Enable Jitter Measurements checkbox, and select individual buttons to configure the
application to display desired jitter results.