Operator's manual – Teledyne LeCroy Serial Data Debug Solutions User Manual
Page 67

Operator's Manual
919586 RevA
67
5.
D
ATA
P
ATTERN
S
ETUP
Data Value - Provide an appropriate value based on your Binary or Hexadecimal format selection.
Data Value To - Specify a size in bits for your pattern.
Condition - Possible entries for this field include Equal, Not Equal, Less than, Less than or Equal to,
Greather than, Greater than or Equal to, In Range, or Out Range.
Pattern Length - The pattern length value defaults to the length, in bytes, of the pattern set in the Data
Value selection. If the length is changed to a lesser value, it truncates the beginning of the value. If the
length is increased, it would add don’t care XX byte values to the beginning of the value.
6.
I
NTER
F
RAME
S
ETUP
Click the appropriate button to select None or Manual. The Manual button enables the Byte Position and