Vanguard CT-6500 S2 User Manual

Page 45

Advertising
background image

CT-6500 Series 2 Operating Instructions

44

9.6 Recalling a Timing Test Record

The following steps in Table 11.0 are used to recall a timing test record stored in the EEPROM

to the working memory. Once a test record is recalled, the user can get a printout of the test
results from the thermal printer.

Table 11.0 Recalling a Timing Test Record

STEP OPERATION

ACTION

DISPLAY

1

SELECT SETUP MENU.

PRESS #3 KEY.

1.ANALYSIS POINT

2.MEASUREMENT UNITS

3.SAVE / RESTORE

4.NEXT PAGE

2

SELECT SAVE/RESTORE SHOT.

PRESS # 3 KEY.

1.SAVE SHOT

2.RESTORE SHOT

3.SHOT DIRECTORY

4.ERASE SHOT

3

SELECT RESTORE SHOT.

PRESS #2 KEY.

ENTER SHOT NUMBER
TO BE RESTORED

XXXX

"ENTER" TO CONFIRM

4

ENTER SHOT NUMBER “1” TO BE

RESTORED.

PRESS KEYS 0-9

FOR SHOT ID THEN

PRESS THE

"ENTER" KEY.

ENTER SHOT NUMBER
TO BE RESTORED

0001

"ENTER" TO CONFIRM

5

CONFIRM SHOT TO BE RESTORED.

PRESS THE

"ENTER" KEY.

RESTORING SHOT # 0001

TEST: OPEN

DATE: 06\12\07 09:12

"ENTER" TO CONFIRM

6

CONFIRM TEST RESTORED.

NONE.

RESTORE COMPLETE

7

RETURN TO MAIN MENU.

PRESS ANY KEY.

1.RUN TEST 06/10/07

2.GET RESULTS 20:10:01

3.SETUP

4.DIAGNOSTIC

Advertising