M- a2 b+ b – Vestil EPT-30 User Manual
Page 15

15
Curtis PMC 1207/1207A Manual
8
WIRING: Compound Motor Configuration
A specially configured controller is available for compound motor applications.
The wiring for a compound wound motor with armature reversing is shown in
Figure 4.
2 — INSTALLATION & WIRING: 1207 Controller
Fig. 4
Compound
motor wiring diagram,
Curtis PMC 1207
controller.
The configuration shown in Figure 4 requires the use of a compound wound
motor. Pure shunt motors cannot be used with 1207 controllers. Although
the configuration shown is typical, various other configurations are possible.
NOTE
: The emergency reverse check feature (wiring shown by dashed line) is a
factory option.
MULTI
MODE
EMERGENCY
REVERSE
A2
A1
REVERSE
CONT
ACT
OR
PRECHARGE RESISTOR
(250
Ω, 5 W)
BRAKE
FWD
CONTACTORS
MAIN
REV
SWITCHES
CONTROL
FUSE
M-
A2
B+
B-
FORWARD
CONTACTOR
POWER
FUSE
KEYSWITCH
POLARITY
PROTECTION
DIODE
S1
S2
MAIN
CONTACTOR
B-
B+
FORWARD
REVERSE
SHUNT
THROTTLE
5k
Ω–0 (TYPICAL)
A