Warner Electric CBC-300C Dual User Manual

Page 11

Advertising
background image

Internal Adjustments

The internal DIP Switch on the control circuit board adjusts the control for the proper current range to
the clutch and/or brake coil being used. The Chart below indicates the proper setting based on coil
resistance and Warner Electric product. To adjust for products not listed, obtain coil resistance
information and set switches per coil resistance.

Switch DIP No.

1

2

3

4

5

Coil Resistance

1000-1550

350-999

250-349

205-249

100-204

at 20° C (W)

Current Range

0 - 60 ma

0 - 175 ma

0 - 245 ma

0 - 305 ma

0 - 533 ma

Warner Electric

SF-120

EC-375

ATC-25

SF-500

ATC-115

Clutch Models

SF-170

EC-475

PC-500

SF-650

SF-1525

SF-250

EM-50

SF-825

SF-825BM

(Not SF-1525HT

SF-400

EM-100

PC-1000

PC-825

Models)

EM-180

SF-1225

SF-1000

UM-50

PC-1225

EC-650

UM-100

PC-1525

EC-825

UM-180

EC-1000

EC-1225

UM-50C

EM-210

ATC-55

UM-180C

UM-210

EUM-50

UM-215

EUM-100

UM-210C

EUM-180

EUM-210
EUM-215

Warner Electric

PB-120

EB-375

ATB-25

EB-825

EMFB-210

Brake Models

PB-170

EB-475

PB-500

EMFB-180

UMFB-210

PB-250

EM-50

PB-650

UMFB-180

ER/FB-650

PB-400

EM-100

PB-1000

ER/FB-475

ATB-115

EM-180

PB-1225

ATB-55

UM-50

PB-1525

ER-825

UM-100

EB-650

UM-180

EB-1000

UM-50C

EB-1225

UM-180C

EMFB-50

EUM-50

UMFB-50

EUM-100

ER/FB-375

EUM-180

EM-210

UM-210
UM-215

UM-210C

EUM-210
EUM-215

Note: Only one switch number is to be set to the “on” position at any time.