Warner Electric CBC-300C Dual User Manual

Page 3

Advertising
background image

3

Warner Electric • 800-825-9050

P-269-1

Specifications

Input Power: 120 VAC, +10%, -15%, 50/60 Hz,

single phase, 215 VA maximum.

Output: Pulse-width modulated full wave rectified

DC. Constant current, switch selectable ranges
designed for 90 volt DC clutches and brakes.

Ambient Temperature: -32°F to + 113°F (0°C to +

45°C) with plastic cover installed. -32°F to
+150°F (0°C to + 66°C) with plastic cover
removed, or board assembly only.

Circuit Protection: Internal short circuit protection

on outputs, but no circuit protection for AC
ground faults. Optional customer supplied
fusing on AC line, 1.5 amps, 250 VAC Fast-
Acting type fuse recommended.

Control Adjust: CBC-300 and CBC-300-C via front

panel potentiometer for current adjustment.
CBC-300-1 and CBC-300-C1 via external
mounted potentiometer for current adjustment.

CBC-300-2 and CBC-300-C2 current
adjustment via front panel potentiometer and
output level adjust via external potentiometer.

CBC-300-3 and CBC-300C3 both current
adjust and limit adjustment are via external
potentiometers.

Status Indicators: “POWER” – green LED indicating

AC power is applied to the control.

“SHORT” – red LED indicating that a short
circuit condition exists on one or both of
the outputs.

Internal Adjustments: Current Range Selection via

DIP switches, SW1 for Channel 1 and SW2 for
Channel 2.

Current Ranges:

Switch Setting

1

2

3

4

5

Max Output, ma

60

175

245

305

533

External Switching: Mechanical or Electro-mechanical

Switching: Customer supplied, 1 amp, 125 V
minimum rating.

Solid-state NPN isolated transistor
Customer supplied, 2 amp, 250V minimum
rating. Maximum off state leakage current < 1
ma.

External Pots:

Remote current adjust pot
Customer supplied: 10,000 ohm, 2 watt, linear,
maximum distance from control to
potentiometer not to exceed 10 feet.

Optional Accessory Pot Kit;
part number, 6011-101-002

Remote Level Adjust Pot
Customer supplied: 5,000 ohm, 2 watt, linear,
maximum distance from control to
potentiometer not to exceed 10 feet.

Optional Accessory Pot Kit:
part number, 6011-101-001.

Wiring Entrance: Two 7/8” diameter entrance holes

located on the bottom of the control chassis on
enclosed units. No conduit entrances are on
chassis mount versions.

Enclosure: Rated NEMA 1 only – Control must be

kept clear of foreign materials, dust, grease and
oil which might affect its operation.

Part Numbers:

Enclosed Versions

CBC-300

6021-448-001

CBC-300-1

6021-448-002

CBC-300-2

6021-448-003

CBC-300-3

6021-448-004

Chassis Versions
CBC-300-C

6021-448-005

CBC-300-C1

6021-448-006

CBC-300-C2

6021-448-007

CBC-300-C3

6021-448-008