External Level Adjustment with Internal
Current Limit Adjust

q 1. Wire the external level adjustment

potentiometer on Terminal Block TB-2 as
shown in the diagram. (See Figure 5)

q 2. If the optional accessory potentiometer kit

is used, wire the potentiometer per the colors
as shown in the diagram.

q 3. Make sure all terminals are securely

fastened and the wiring cable is secured so
that it can’t pull loose from the terminals.

Note: The level adjustment controls both the
Channel 1 and Channel 2 outputs from 0
maximum as set by the current limit adjust
potentiometers.

q 4. After the pot(s) have been wired to the

appropriate terminal block(s), mount the PCB
and bracket assembly and reattach to the
chassis with the four screws removed in step
2 above.

q 5. For the CBC-300-2 reattach the internal

potentiometer knobs.

q 6. Double check all wiring connections for the

potentiometer(s) and the main terminal block
to insure proper connections.

CBC-300-3

External Current Limit and Level Adjust

q 1. Wire the external current limit adjust

potentiometer to Terminal Block TB-3 for
Channel 1 and Terminal Block TB-4 for
Channel 2 as shown in the diagram. (See
Figures 6 & 7)

q 2. If the optional accessory potentiometer kits

are used, wire per the color codes as shown
in the diagram.

q 3. Make sure all terminals are securely

fastened and the wiring cables are secured
so that it can’t pull loose from the terminals.

q 4. Wire the external level adjust potentiometer

to Terminal Block TB-2 as shown in the
diagram. (See Figure 5)

q 5. If the accessory potentiometer kit is used,

wire per the color codes as shown in the
diagram.

q 6. Make sure all terminals are securely

fastened and the wiring cable is secured so
that it can’t pull loose from the terminals.

Note: The level adjustment controls both
Channel 1 and Channel 2 outputs from 0
maximum level as set by the current limit adjust-
ment potentiometers.

CBC-300-2, CBC-300-2C

External Level Adjust w/Internal

Current Limit Adjust

RED

BLK

CW

5K POT

10 FT MAX

LEVEL

1

TB2

2

TB-2

(Figure 5)