Tb-3, Tb-4 – Warner Electric CBC-300C Dual User Manual

Page 8

Advertising
background image

8

Warner Electric • 800-825-9050

P-269-1

External Potentiometer wiring for
CBC-300 Series Controls

Enclosed Models
CBC-300-1
CBC-300-2
CBC-300-3

Depending on which control is being used,
options for external potentiometer are available
via terminal blocks on the PC board of the unit.

q 1. For CBC-300-2 only, remove the internal

torque adjust knob.

q 2. Remove the four screw that hold the

bracket assembly and PC Board to the
chassis. This step applies to all versions of
the enclosed models.

q 3. Based on which model being used, route

the potentiometer cable(s) through one of the
conduit entrance holes on the bottom of the
unit and wire to the appropriate terminal
block on the PC board. Refer to the wiring
diagrams below for the proper connections.

CBC-300-1
External Current Limit Adjustment

q 1. Wire the external current limit

potentiometer to Terminal Block TB-3 for
Channel 1 and TB-4 for Channel 2 as shown
in the diagram. (See Figures 6 & 7)

q 2. If the accessory potentiometer kit is used,

wire the potentiometers per the colors as
shown in the diagram.

q 3. Make sure all terminals are securely

fastened and the wiring cable is secured so
that it can’t pull loose from the terminals.

CBC-300-1, CBC-300-1C

External Current

Limit Adjust

WHT

RED

BLK

CW

10K POT

10 FT MAX

CH1

TB3

3

2

1

TB-3

(Figure 6)

CBC-300-1, CBC-300-1C

External Current

Limit Adjust

WHT

RED

BLK

CW

10K POT

10 FT MAX

10K, 2W POT

10% TOL, LINEAR OR

6011-101-002

ACCESSORY KIT (1)

CH2

TB4

3

2

1

TB-4

(Figure 7)

Advertising