Waterstone UNDER SINK SYSTEMS 4500 User Manual

Page 3

Advertising
background image

A

B

C

D

E

F

G

Water from the blue supply tube (A) flows
through the PRV valve (B) and into the
faucet base (C). Water is then diverted into
the red tube (D) and into the Hot Tank (E).
The entering water displaces hot water in
the tank causing it to flow freely through
the clear “high temp” tube (F). Hot water
continues straight through the faucet and
exits the spout (G).

IMPORTANT - NEVER OPERATE THE

FAUCET WITH A KINKED CLEAR

OUTLET TUBE

Installation of the Pressure Regulator

Valve (PRV) is required to maintain

your warranty

OUTLET

INLET

G

J

K

L

M

N

P

H

1.

COUNTER

OR SINK

2.

3.

4.

Slide washer (N) and thread
the nut (P) onto threaded
shroud. Hand tighten nut
underside of sink or counter.

Turn faucet to the desired
handle position. Securely
tighten nut with adjustable
wrench.

FILTRATION FAUCET INSTALLATION

HOW A VENTED FAUCET WORKS

NEVER!

Slide escutcheon plate (G) and
clear vinyl washer (H) onto
threaded shroud (J) and up to
base of faucet.

Fit flexible hoses (K, L, M)
through hole on counter or
sink. (No plumbers putty is
required. Vinyl washer seals
base)
.

CONNECTION TO A FAUCET OTHER THAN

A 3-LINE VENTED WILL VOID WARRANTY

AND CAUSE INTERNAL DAMAGE TO TANK

CONNECT A #5000 HOT TANK TO A FAUCET

AS SHOWN

Advertising