EXTERNAL SYNCHRONIZATION

(VZ-37 and VZ-17 only!)

If Visualizer images are mixed and processed (fade-in, fade-out, mix/wipe) with images from one or more video cameras (or
Visualizers) using a special effect unit without TBC (time base corrector), all units connected must be genlocked.

Genlocking is achieved by supplying the same composite video signal (VBS) or black burst (BB) signal to the Extern Sync
input (=Genlock input) of each unit connected.

In order to genlock the WolfVision Visualizer with another video signal, simply connect this signal to the Sync input (#33) of
the Visualizer where a composite video or a black burst signal can be connected.

With a VZ-37 fine adjustment of color-phase (SC) and H-phase can be made in the unit's on-screen menu.

With a VZ-17 it is necessary to open the unit and adjust the settings with a screwdriver on the camera itself. Please leave
this to a technically experienced person, as there is sensitive and potentially dangerous electronics inside the unit!

Start with H-phase adjustment, followed by rough adjustment of "0/180" followed by fine adjustment with SC.

Genlock operation with a playback signal of a video recorder is only possible if the signal is time base corrected via a TBC
device.

15

* Parallel GND is the ground for the opto-isolated control inputs. DC GND is the ground for DC + 12 V and also for Video out.
If you want to use DC + 12 V for the control inputs make a connection between DC GND and Parallel GND.
** If the relay is open: Resistor value at least 3k3.

Parallel port

(15-pin D-Sub, 12-24 V)

Serial port

Serial protocol

1. Relay-Out (closed if the arm is complete down) **
2. Lock Arm (if activated, no arm function is possible)
3. Power ON
4. Power Off
5. Arm Up
6. Arm Down
7. Parallel GND *
8. DC +12 V
9. Light On/Off
10. Zoom Tele
11. Zoom Wide
12. Mirror Up
13. Mirror Down
14. Shift inactive
15. GND

15-pin D-Sub connector, 12-24V
on unit, male, front side

Pins: 2:RX, 3:TX, 5:GND

9-pin D-Sub connector
on unit, male, front side

CONTROL CONNECTORS

(all Visualizers)

A detailed description of the serial protocol (including status
report and position setting) is available on request from your
WolfVision dealer or can be downloaded from our website:
http://www.wolfvision.com/wolf/techinfo.html.

1. Relay-Out
2. Focus near
3. Focus far
4. Iris open
5. Iris close
6. Image On/Off
7.
8. DC +12 V

(closed if the arm is complete down) **

Parallel GND *

9. Preset1
10. Preset 2
11. Preset 3
12. Text Enhancement
13. Macro On/Off
14. Shift active
15. GND

First Function, Shift key is not activated

Second Function, Shift key is activated