ZOLL AED Plus Rev C User Manual

Zoll, Aed plus, Administrator’s guide insert

Advertising
background image

9652-0839-01 Rev. C

II

II

R1345-98 Rev. F

pedi

Infant/Child Electrodes

<55lbs / 25kg

2

1

3

s / 25kg

<55lbs

3

s / 2

®

®

U.S. Pat. No's. 5,330,526
5,462,157

ONLY

Rx

32°F

0° C

50°C

122° F

Multi-function

ZOLL Medical Corporation
269 Mill Road
Chelmsford, MA 01824-4105 USA
800-348-9011 Made in USA

ZOLL International Holding B.V.
Newtonweg 18 6662 PV ELST
The Netherlands Tel. +31 (0) 481 366410

®

0-8 Years

non-invasive pacing

cardioversion ecg monitoring

defibrillation

ZOLL

®

AED Plus

®

Administrator’s Guide Insert

Important: This symbol indicates that the AED Plus unit is equipped for
treating adult and pediatric patients. An AED Plus unit without this symbol is not
equipped to treat pediatric patients and will not work with the Pedi-padz

®

II pediatric

electrodes. To upgrade an AED Plus unit for use with ZOLL Pedi-padz II pediatric
electrodes, contact ZOLL Medical Corporation or an authorized ZOLL distributor for
information on the ZOLL AED Plus Pediatric Upgrade Kit.

If an AED Plus unit is equipped for treating adult and pediatric patients, when you

connect the cable for adult electrodes, the AED Plus unit switches automatically to adult mode for cardiac
rhythm detection and automatic shock energy selection (120 Joules, 150 Joules, 200 Joules) and issues the
voice and display prompt , ADULT PADS. When you connect the cable for ZOLL Pedi-padz II pediatric
electrodes, the AED Plus unit switches automatically to pediatric mode for cardiac rhythm detection and
automatic shock energy selection (50 Joules, 70 Joules, 85 Joules) and issues the voice and display
prompt, PEDIATRIC PADS.

Applying Pedi-padz II (Infant/Child) Electrodes

Prepare the patient before attaching the pedi-padz II electrodes.

To prepare the patient:
1. Remove all clothing covering the patient’s chest.
2. Ensure the patient’s chest is dry.

To apply the Pedi-padz II electrodes:
1. Tear open the electrode package and unfold the inner package to expose the electrodes. Place the

electrodes on the patient according to the graphics on the
electrode package.

2. Remove the round electrode from its backing material and place it

on the patient’s chest (as shown on the electrode package graphics).

3. Place your hand on the electrode edge and, using the other

hand, gently roll the electrode onto the patient’s chest, pushing any

air out from beneath the electrode as you go.

4. Roll the patient onto his/her chest, remove the square electrode

from its backing and place it on the patient’s back (as shown on the

electrode package graphics).

5. Place your hand on the electrode’s edge and, using your other

hand, gently roll the electrode onto the patient’s skin, pushing any

air out from beneath the electrode as you go.

6. Roll the patient onto his/her back and follow the ZOLL AED Plus
prompts.

NOTE

You can also use Pedi-padz II (infant/child electrodes) with ZOLL pacemaker products for up to

one hour of pacing (see the M Series Operator’s Guide for information about pacing).

Indications for Use


Use the ZOLL AED Plus when a suspected cardiac arrest victim has an apparent LACK OF CIRCULATION
as indicated by


 Unconsciousness;

and

Absence of normal breathing; and

Absence of a pulse or signs of circulation.


When the victim is less than 8 years of age and weighs less than 55 lbs (25 kg), the ZOLL AED Plus should
be used with the ZOLL AED Plus Pediatric Electrodes. Therapy should not be delayed to determine the
patient’s exact age or weight.

Advertising