Page 93

KINO-DH810
P a g e 81
Full Mode
Fan is on all the time
Manual PWM Mode
The fan spins at the speed set in the
manual PWM setting
Auto PWM Mode
D
EFAULT
The fan adjusts its speed using these
settings:
Temperature of Start
Temperature of Off
Start PWM
Slope (Duty Cycle)
Tem p eratu re o f Off [75]
WARNING:
Setting this value too high may cause the fan to speed up only when
the CPU is at a very high temperature and therefore cause the system
to be damaged.
The Temperature of Off option can only be set if the CPU Smart Fan control option is
set to Auto Mode. When the CPU Temperature is lower than Temperature of Off, the
fan speed change to be lowest. To set a value, select the Temperature of Off option and
enter a decimal number between 0 and 127. The temperature range is specified below.
Minimum Value: 0°C
Maximum Value: 127°C
Tem p eratu re o f Start [80]
WARNING:
Setting this value too high may cause the fan to rotate at full speed only
when the CPU is at a very high temperature and therefore cause the