IEI Integration NANO-QM57A User Manual
Page 82

NANO-QM57A EPIC SBC
Page 70
Î
Auto RPM Mode
D
EFAULT
The fan adjusts its speed using these settings by
RPM:
First Boundary Temperature
Second Boundary Temperature
Third Boundary Temperature
Fourth Boundary Temperature
Segment 1 Speed Count
Segment 2 Speed Count
Segment 3 Speed Count
Segment 4 Speed Count
Segment 5 Speed Count
Starting Full Speed Count
Î
Auto Duty Cycle
Mode
The fan adjusts its speed using these settings by
Duty Cycle:
First Boundary Temperature
Second Boundary Temperature
Third Boundary Temperature
Fourth Boundary Temperature
Segment 1 Speed Count
Segment 2 Speed Count
Segment 3 Speed Count
Segment 4 Speed Count
Segment 5 Speed Count
Î
Manual RPM Mode
The fan spins at the speed set in:
Expect speed count value
(Min=1000 rpm, Max=15000 rpm)
Î
Manual Duty Cycle
Mode
The fan spins at the speed set in:
Expect Duty Cycle
(Min=0%, Max=100%)