INSTALLATION

AutoDrive

®

19 Tandem

A-3

AUTODRIVE

®

19 TANDEM DESCRIPTION

1

5

4

3

2

®

®

1. STATUS LED

The status light is a two color LED. Normal operation
is steady green. Flashing green or red/green indi-
cates a system error. See the troubleshooting sec-
tion.

Note: At power up of the Power Wave

®

system, the sta-

tus light will flash green for up to 60 seconds.
This is normal and indicates that the system is
performing a self test and mapping each compo-
nent in the local ArcLink system. The status lights
will also flash green as a result of a system reset
or configuration change during operation. When
the status lights become steady green, the system
is ready for operation.

2. ARCLINK INPUT CONNECTOR (5 PIN):

Receives power and communication from the power
source

3. ARCLINK OUTPUT CONNECTOR (5 PIN):

Provides power and communication to the robotic
controller.

4. 14 PIN CONNECTOR:

Provides motor power, tach feedback, solenoid drive
and electrode sense (67) between the AutoDrive

®

19

controller and the wire feeder.

5. EXTERNAL I/O CONNECTOR:

Terminal Strip for making simple input signal connec-
tions. (See Figure A.2)
The terminal strip is divided into three groups:

Group #1 - TRIGGER
Group #2 - FEED FORWARD/REVERSE
Group #3 - SHUTDOWN INPUTS

When the Power Wave Power Source is controlled via
DeviceNet, the “TRIGGER” and “Feed” groups can
interfere with the welding sequence and should not be
used.

All inputs use "normally open" logic except the shut-
down group. The shutdown inputs use "normally
closed" logic, and are always enabled. Unused shut-
downs must be tied to the +15V supply for the shut-
down group. Machines are shipped from the factory
with jumpers installed on both shutdown inputs.

SELECTING A WIRE DRIVE
AND GEAR RATIO

The AutoDrive

®

19 Tandem can accommodate a num-

ber of wire drives including the AutoDrive

®

4R100,

AutoDrive

®

4R220 and Power Feed

®

10R. The feeder

control system must be configured for both the wire
drive and the gear ratio. This can be accomplished
with the Power Wave

®

Manager Utility. This utility is

available at
www.powerwavesoftware.com.

1

2

3

4

5

6

7

8

9

10

11

12

+15VDC - Group #1

T

rigger

Dual Procedure

+15VDC - Group #2

Feed Forward

2/4

St

ep

Gas Purge

Feed Reverse

+15VDC - Group #3

Shutdown 1 Input

Shutdown 2 Input

FIGURE A.1

FIGURE A.2