Installation, Temperature range, Physical dimensions – Lincoln Electric IM10080 RED-D-ARC LN-25 PRO EXTREME DUAL POWER User Manual

Page 10: Gearing - wire feed speed range-wire size

Advertising
background image

A-1

INSTALLATION

A-1

RED-D-ARC LN25™ PRO EXTREME DUAL POWER

TEMPERATURE RANGE

OPERATION:

-40°F to 104°F (-40°C to 40°C)

STORAGE:

-40°F to 122°F (-40°C to 50°C)

INPUT VOLTAGE and CURRENT

TECHNICAL SPECIFICATIONS – RED-D-ARC LN25™ PRO EXTREME DUAL POWER

(K2614-7)

HEIGHT

WIDTH

DEPTH WEIGHT

14.8 Inches

8.7 Inches 23.2 Inches 40 lbs

(376 mm) ( 221 mm)

(589 mm) (18 kg)

Handle folded down

PHYSICAL DIMENSIONS

INPUT VOLTAGE ± 10%

Across the Arc configuration

15-110 VDC

Control Cable configuration

24-42 VAC

INPUT AMPERES

4A

RATED OUTPUT @ 104°F (40°C)

DUTY CYCLE

60% rating

INPUT AMPERES

450

GEARING - WIRE FEED SPEED RANGE-WIRE SIZE

WFS RANGE

50 – 700 ipm

(1.3 – 17.7m/min)

WFS RANGE

50 – 700 ipm

(1.3 – 17.7m/min)

WIRE SIZES

.023 – 1/16"

(0.6 – 1.6mm)

WIRE SIZES

.030 - 5/64

(0.8 - 2.0mm)

GEARING

Standard Speed

Thermal tests have been performed at ambient temperature. The duty cycle (duty factor) at 40°C has been
determined by simulation.

Duty cycle is based upon the amount of welding performed in a 10 minute period.

GMAW

FCAW

Advertising