WELD CABLE SIZE

Table A.1 located below are copper cable sizes rec-
ommended for different currents and duty cycles.
Lengths stipulated are the distance from the welder to
work and back to the welder again. Cable sizes are
increased for greater lengths primarily for the purpose
of minimizing cable drop.

** Tabled values are for operation at ambient temperatures of 104°F(40°C) and below. Applications above 104°F(40°C) may require cables

larger than recommended, or cables rated higher than 167°F(75°C).

RECOMMENDED CABLE SIZES (RUBBER COVERED COPPER - RATED 167°F or 75°C)**

CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK CABLES

AMPERES

200
200
225
225
250
250
250
250
300
325
350
400
400
500

PERCENT

DUTY

CYCLE

60

100

20

40 & 30

30
40
60

100

60

100

60
60

100

60

0 to 50Ft.
(0 to15m)

2
2

4 or 5

3
3
2
1
1
1

2/0
1/0
2/0
3/0
2/0

50 to 100Ft.

(15 to 30m)

2
2
3
3
3
2
1
1
1

2/0
1/0
2/0
3/0
2/0

100 to 150 Ft.

(30 to 46m)

2
2
2
2
2
1
1
1
1

2/0
2/0
2/0
3/0
3/0

150 to 200 Ft.

(46 to 61m)

1
1
1
1
1
1
1
1

1/0
2/0
2/0
3/0
3/0
3/0

200 to 250 Ft.

(61 to 76m)

1/0
1/0
1/0
1/0
1/0
1/0
1/0
1/0
2/0
3/0
3/0
4/0
4/0
4/0

TABLE A.1

A-2

INSTALLATION

RED-D-ARC LN25™ PRO EXTREME DUAL POWER

A-2

SAFETY PRECAUTIONS

ELECTRIC SHOCK CAN KILL.
• Turn the input power OFF at the

disconnect switch or fuse box
before attempting to connect or
disconnect input power lines, out-
put cables or control cables.

• Only qualified personnel should

perform this installation.

• Do not touch metal portions of the work clip

when the welding power source is on.

• Do not attach the work clip to the wire feeder.
• Connect the work clip directly to the work, as

close as possible to the welding arc.

• Turn power off at the welding power source

before disconnecting the work clip from the
work.

• Only use on power sources with open circuit

voltages less than 110 VDC.

------------------------------------------------------------------------

LOCATION

For best wire feeding performance, place the RED-
D-ARC LN25™ PRO EXTREME DUAL POWER on
a stable and dry surface. Keep the wire feeder in
a vertical position. Do not operate the wire feeder
on an angled surface of more than 15 degrees.

Do not submerge the RED-D-ARC LN25™ PRO
EXTREME DUAL POWER.

The RED-D-ARC LN25™ PRO EXTREME DUAL
POWER is rated IP23 and is suitable for outdoor
use.

The handle of the RED-D-ARC LN25™ PRO
EXTREME DUAL POWER is intended for moving
the wire feeder about the work place only.

When suspending a wire feeder, insulate the
hanging device from the wire feeder enclosure.

HIGH FREQUENCY PROTECTION

Locate the RED-D-ARC LN25™ PRO EXTREME
DUAL POWER away from radio controlled machin-
ery. The normal operation of the RED-D-ARC
LN25™ PRO EXTREME DUAL POWER may
adversely affect the operation of RF controlled
equipment, which may result in bodily injury or
damage to the equipment.

------------------------------------------------------------------------

WARNING

CAUTION