Arc volts, Operation, Constant current operation – Lincoln Electric IM10080 RED-D-ARC LN-25 PRO EXTREME DUAL POWER User Manual

Page 23

Advertising
background image

B-3

OPERATION

B-3

RED-D-ARC LN25™ PRO EXTREME DUAL POWER

The serviceability of a product or structure utiliz-
ing the RED-D-ARC LN25™ PRO EXTREME DUAL
POWER wire feeder is and must be the sole
responsibility of the builder/user. Many variables
beyond the control of The Lincoln Electric
Company affect the results obtained in using the
RED-D-ARC LN25™ PRO EXTREME DUAL POWER
wirefeeder. These variables include, but are not
limited to, welding procedure, plate chemistry and
temperature, weldment design, fabrication meth-
ods and service requirements. The available
range of the RED-D-ARC LN25™ PRO EXTREME
POWER wirefeeder may not be suitable for all
applications, and the builder/user is and must be
solely responsible for welding settings.

CONSTANT CURRENT OPERATION

Setting Wire Feed Speed in CC mode

When Across the Arc models are operated with CC
power sources, the wire feed speed changes as the
arc voltage changes. When the arc voltage increases,
the wire feed speed will increase; and when the arc
voltage decreases, the wire feed speed will decrease.

To preset the wire feed speed on CC power sources:

1. Set the Wire Feed Mode switch inside the LN25™

Pro to "CC".

2. Refer to the Figure B.1a graph for the setting for

the wire feed speed knob setting. Select the hori-
zontal line representing the Desired Wire Feed
Speed. (See Figure B.1a arrow for 375 in/min.)

3. Select the diagonal line representing the Arc

Volts. (See Figure B.1a for 29 volts.)

4. Determine the vertical line representing the CC

representing the CC Wire Feed Speed setting
where the above two lines cross. (See Figure
B.1a arrow line for 450.) Set the LN25™ Pro
wire feed speed knob to this value.

CC WFS dial setting = desired WFS x 35

Arc Volts

Example:

375 in/min. (Horizontal Line) x 35
29 Arc Volts (Diagonal Line)

= 452.5 (Vertical Line)

(See Figure B.1)

50

100

150

in/min.

200

250

300

350

375

400

450

500

550

600

650

700

50

100

150 200

250

300

350

400

450

500

550

650

700

35

31

29

27

25

23

21

19

17

15

33

600

ARC
VOLTS

CC

FIGURE B.1

A constant voltage (CV) power
source is recommended for flux-
cored arc welding. (FCAW) and
gas metal arc welding (GMAW) to
obtain code quality results.
However, this wire feeder may also
be used with a constant current
(CC) power source to obtain pass-
able results for noncritical quality
applications.

=

Use 450 setting

Advertising