background image

A-3

INSTALLATION

MAXsa™ 19 CONTROLLER

A-3

FIGURE A.1 - CONNECTION DIAGRAM

K2683-XX

Arclink Cable

67 Lead

K1785-XX

14-Pin Cable

Work

K231-XX

Contact Nozzle

K2803-1

Power Wave

®

AC/DC 1000 SD

K2312-2

(For Codes 11778 and above)

MAXsa

29

K1811-XX

Sense Lead

Electrode

Weld Cable

Work

Weld Cable

Connection Diagrams for Additional

Configurations (Multi-Arc and Parellel Power Sources)

are in the Power Wave

®

AC/DC 1000 SD Operators Manual

K2626-2
MAXsa

19

K1543-XX or

INTERFACING TO THE MAXsa™ 19 CON-
TROLLER

The MAXsa™ 19 is a versatile controller designed to
operate in a Power Wave

®

AC/DC 1000 SD system

and is responsible for relaying wire feed commands to
a MAXsa™ 29 Wire Drive. It is connected to the Power
Wave

®

AC/DC 1000 SD by a K2683-xx ArcLink Cable

and to the Wire Drive by a K1785-xx 14 Pin Control
Cable.

The MAXsa™ 19 is required whenever a customer
supplied user interface is used in place of a MAXsa™
10 Controller.