Troubleshooting, Caution – Lincoln Electric IM10021 MAXsa 19 CONTROLLER User Manual

Page 20

Advertising
background image

E-4

TROUBLESHOOTING

E-4

Observe all Safety Guidelines detailed throughout this manual

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.

Err 84 Shutdown #2 is open.

Err 6311 Unstable or “noisy” wire

feed speed (WFS) feed-
back signal.

1.This refers to the ʻgreenʼ I/O con-

nector on the bottom of the con-
troller.

If not being externally
accessed, verify the integrity of
the connector and jumper.

If accessed through a remote
circuit, verify the integrity of that
circuit.

1. Check the cables and connec-

tions to the Wire Drive.

2. Check the Wire Drive control

cable routing (see Control Cable
Connection- General Guidelines).

3. Check the Tachometer Interface

Board.

ARCLINK SYSTEM ERROR CODES

MAXsa™ 19 CONTROLLER

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Advertising