Installation, A-5 external i/o connector, Status light – Lincoln Electric IM10021 MAXsa 19 CONTROLLER User Manual

Page 12: Selecting a wire drive and gear ratio

Advertising
background image

A-5

INSTALLATION

MAXsa™ 19 CONTROLLER

A-5

EXTERNAL I/O CONNECTOR

The MAXsa™ 19 is equipped with a terminal strip for
making simple input signal connections.(See Figure
A.3)

The terminal strip is divided into three groups:

Group #1 - START / STOP

Group # 2 - FEED FORWARD/REVERSE

Group #3 - SHUTDOWN INPUTS

When the Power Wave AC/DC 1000 SD is controlled
via DeviceNet, the “Start/Stop” and “Feed” groups can
interfere with the welding sequence and should not be
used.

All inputs use "normally open" logic except the shut-
down group. The shutdown inputs use "normally
closed" logic, and are always enabled. Unused shut-
downs must be tied to the +15V supply for the shut-
down group. Machines are shipped from the factory
with jumpers installed on both shutdown inputs. See
Figure A.4 for input Identification.

NOTES

1. Activating the “Start/Stop” or “Feed” group inputs

on a system without a user interface or other
means of configuring the Weld Sequencer will
result in default values for Weld Mode, WFS and
Work point settings.

2. “Start/Stop” and “Feed” group inputs may be rede-

fined as "Weld Profile Selections" by Production
Monitoring software (see Production Monitoring
Literature for details).

STATUS LIGHT

The Status Light is a two color LED that indicates the
system condition. Normal operation is steady green.
Flashing green or red/green indicates a system error.
See the Troubleshooting Section.

SELECTING A WIRE DRIVE
AND GEAR RATIO

The MAXsa™ 19 can accommodate a number of wire
drives including the MAXsa™ 22 and MAXsa™ 29.
The feeder control system must be configured for both
the wire drive and the gear ratio. This can be accom-
plished with the Weld Manager Utility. This utility is on
the Power Wave Submerged Arc Utilities CD, or avail-
able at www.powerwavesoftware.com.

FIGURE A.3 - EXTERNAL I/O

1

2

3

4

5

6

7

8

9

10

11

12

FIGURE A.4

E

1

2

3

4

5

6

7

8

9

10 11 12

A

B

+15VDC - Gr

oup #1

ST

AR

T

ST

OP

+15VDC - Gr

oup #2

Feed F

or

w

ar

d

Feed Rev

erse

+15VDC - Gr

oup #3

Shut

do

wn 1 I

nput

Shut

do

wn 2 I

nput

C

D

F