Installation, Control cable connections, A-11 – Lincoln Electric IM10133 POWER WAVE R500 User Manual

Page 17

Advertising
background image

A-11

INSTALLATION

POWER WAVE

®

R500

A-11

CONTROL CABLE CONNECTIONS

General Guidelines

Genuine Lincoln control cables should be used at all
times (except where noted otherwise). Lincoln cables
are specifically designed for the communication and

power needs of the Power Wave

®

/ Power Feed

sys-

tems. Most are designed to be connected end to end
for ease of extension. Generally, it is recommended
that the total length not exceed 100ft. (30.5m). The
use of non-standard cables, especially in lengths
greater than 25 feet, can lead to communication prob-
lems (system shutdowns), poor motor acceleration
(poor arc starting), and low wire driving force (wire
feeding problems). Always use the shortest length of
control cable possible, and DO NOT coil excess
cable
.

Regarding cable placement, best results will be
obtained when control cables are routed separate
from the weld cables. This minimizes the possibility of
interference between the high currents flowing
through the weld cables, and the low level signals in
the control cables. These recommendations apply to

all communication cables including ArcLink

®

and

Ethernet connections.

Product specific Installation Instructions

Connection Between Power Source and ArcLink

®

Compatible Wirefeeders (K1543, K2683 – ArcLink
Control Cable)

The 5-pin ArcLink control cable connects the power
source to the wire feeder. The control cable consists
of two power leads, one twisted pair for digital com-
munication, and one lead for voltage sensing. The 5-
pin ArcLink connection on the Power Wave

®

R500 is

located on the rear panel (See Case Back Controls in
the Operation Section). The control cable is keyed
and polarized to prevent improper connection. Best
results will be obtained when control cables are routed
separate from the weld cables, especially in long dis-
tance applications. The recommended combined
length of the ArcLink control cable network should not
exceed 200ft. (61.0m).

Connection Between Power Source and Ethernet
Networks

The POWER WAVE

®

R500 is equipped with an IP67

rated ODVA compliant RJ-45 Ethernet connector,
which is located on the rear panel. All external
Ethernet equipment (cables, switches, etc.), as
defined by the connection diagrams, must be supplied
by the customer. It is critical that all Ethernet cables
external to either a conduit or an enclosure are solid
conductor, shielded cat 5e cable, with a drain. The
drain should be grounded at the source of transmis-
sion. For best results, route Ethernet cables away
from weld cables, wire drive control cables, or any
other current carrying device that can create a fluctu-
ating magnetic field. For additional guidelines refer to
ISO/IEC 11801. Failure to follow these recommenda-
tions can result in an Ethernet connection failure dur-
ing welding.

Advertising