E-4

TROUBLESHOOTING

E-4

POWER WAVE

®

R500

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

INPUT CONTROL BOARD

Error Code #

Indication

Type

331 Instantaneous Input Current
Limit

Instantaneous input current limit has been exceeded. Typically
indicates short term power overload. If problem persists contact
Service Department.

Persistent

334 Startup Current Check Failure

Input current limit was exceeded during machine power-up. If
problem persists contact Service Department.

Persistent

335 Startup Voltage Check Failure

Input voltage was too high or too low during machine power-up.
Verify that the input voltage is between 200V and 650V.

Temporary

336 Thermal Fault

Thermostat on primary module tripped. Typically caused by a fan
malfunction or blocked air vent.

Temporary

337 Precharge Timeout

The DC bus voltage was not charged to a certain level at end of
precharge. If problem persists contact Service Department.

Persistent

338 Input Power Limit

The input power drawn by the machine exceeded a safe level. If
problem persists, contact the Service Department.

Persistent

341 Input Voltage Dropout

The input voltage momentarily dropped out. Check connections
and verify quality of input power.

Temporary

346 Transformer Primary
Overcurrent

Transformer current too high. Typically indicates short-term power
overload. If problem persists, contact the Serivce Department.

Persistent

347 Average Input Current Limit

Average input current limit has been exceeded. Typically indicates
short term power overload. If problem persists contact Service
Department.

Persistent

349 Bus Undervoltage

The DC bus voltage dropped below the allowable limit. If problem
persists, contact the Service Department.

Temporary

Persistent errors require power to be cycled for the error to clear.
Temporary faults will go away on their own if the error condition is removed.

WIRE DRIVE MODULE

Error Code #

81 Motor Overload

82 Motor Overcurrent

83 Shutdown #1

84 Shutdown #2

Indication

Long term average motor current limit has been exceeded.
Typically indicates mechanical overload of system. If problem con-
tinues consider higher torque gear ratio (lower speed range).

Absolute maximum motor current level has been exceeded. This is
a short term average to protect drive circuitry.

The Shutdown inputs on the Power Wave R500 have been dis-
abled. The presence of these errors indicates the Feed Head
Control PCB may contain the wrong operating software.