E-2

TROUBLESHOOTING

E-2

POWER WAVE

®

R500

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

USING THE STATUS LED TO
TROUBLESHOOT SYSTEM PROBLEMS

Not all of the POWER WAVE

®

R500 errors will be displayed

on the user interface (if it is installed). There are two status
lights that display error codes. If a problem occurs it is
important to note the condition of the status lights.
Therefore, prior to cycling power to the system, check
the power source status light for error sequences as
noted below.

There is one externally mounted status light located on the
case front of the machine. This status light corresponds to
the main control board and input control boardʼs status.

Included in this section is information about the Status
Lights and some basic troubleshooting charts for both
machine and weld performance.

The status light for the main control board and input control
board are dual-color LEDʼs. Normal operation for each is
steady green.

Error conditions are indicated in the following chart Table
E.1.

Light

Condition

Steady Green

Blinking Green

Fast Blinking Green

Alternating Green and Red

Steady Red

Blinking Red

Status LED off

Meaning

Main control board status light and Input control board

System OK. Power source is operational, and is communicating normally with all healthy peripheral equip-

ment connected to its ArcLink network.

Occurs during power up or a system reset, and indicates the POWER WAVE

®

R500 is mapping (identify-

ing) each component in the system. Normal for first 1-10 seconds after power is turned on, or if the system

configuration is changed during operation.

Indicates Auto-mapping has failed

Non-recoverable system fault. If the Status lights are flashing any combination of red and green, errors are

present. Read the error code(s) before the machine is turned off.

Error Code interpretation through the Status light is detailed in the Service Manual. Individual code digits

are flashed in red with a long pause between digits. If more than one code is present, the codes will be sep-

arated by a green light. Only active error conditions will be accessible through the Status Light.

Error codes can also be retrieved with the Power Wave Manager Utility available at www.power-

wavesoftware.com). This is the preferred method, since it can access historical information contained in

the error logs.

To clear the active error(s), turn power source off, and back on to reset.