Installation, Technical specifications - power wave, R500 – Lincoln Electric IM10133 POWER WAVE R500 User Manual

Page 7

Advertising
background image

A-1

INSTALLATION

POWER WAVE

®

R500

A-1

TECHNICAL SPECIFICATIONS - POWER WAVE

®

R500

RECOMMENDED INPUT WIRE AND FUSE SIZES

1

INPUT

VOLTAGE / PHASE/

FREQUENCY

200-208/3/50/60

230/3/50/60

380-415/3/50/60

460/3/50/60
575/3/50/60

TIME DELAY FUSE

OR BREAKER

2

AMPERAGE

100

90
60
45
35

CORD SIZE

3

AWG SIZES

(mm

2

)

4 (21)
4 (21)
8 (10)
8 (10)
10 (7)

MAXIMUM INPUT

AMPERE RATING AND

DUTY CYCLE

80A, 40%
73A, 40%
41A, 40%
37A, 40%
29A, 40%

RATED OUTPUT

POWER SOURCE-INPUT VOLTAGE AND CURRENT

Model

K3169-1

Duty Cycle

40% rating

100% rating

450 Amps
36.5 Volts

550 Amps
41.5 Volts

500 Amps

39 Volts

INPUT

VOLTAGE/PHASE/

FREQUENCY

200-208/3/50/60

230/3/50/60

380-415/3/50/60

460/3/50/60
575/3/50/60

Input Amperes

80/73/41/37/29

60/54/30/27/21

Idle Power

500 Watts Max.

(fan on)

Power Factor @

Rated Output

.95

Input Voltage ± 10%

208/230/400*460/575

50/60 Hz

(includes 380V to 415V)

1. Based on U.S. National electrical Code

2. Also called " inverse time" or "thermal / magnetic" circuit breakers; circuit breakers that have a delay in trip-

ping action that decreases as the magnitude of the current increases

3. Type SO cord or similar in 30° C ambient at effective current rating of unit.

GMAW

40%

60%

100%

SMAW

GTAW-DC

450 Amps

38 Volts

550 Amps

42 Volts

500 Amps

40 Volts

40%

60%

100%

450 Amps

28 Volts

550 Amps

32 Volts

500 Amps

30 Volts

40%

60%

100%

Advertising