Troubleshooting, Caution – Lincoln Electric IM10003 VANTAGE 500-I User Manual

Page 34

Advertising
background image

E-5

TROUbLESHOOTING

E-5

VANTAGE® 500-I

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PRObLEMS

(SYMPTOMS)

POSSIbLE

CAUSE

RECOMMENDED

COURSE OF ACTION

No welding power output.

Welder has output but no control.

No auxiliary power.

1. Poor work lead connection to

work. Make sure work clamp is
tightly connected to clean base
metal.

2. "Weld Terminals" switch in wrong

position. Place switch in "Weld
Terminals On" position when
welding without control cable.

3. Faulty PC board or welder alterna-

tor.

1. Poor remote/control cable connec-

tion to 6-pin or 14-pin connector.
Check connections.

2. Faulty remote cable or faulty wire

feeder or wire feeder cable.
Replace if necessary.

3. Faulty control potentiometer or PC

board.

1. Open circuit breakers. Reset

breakers. If breakers keep tripping
reduce power draw.

2. GFCI may have tripped.

Follow “GFCI Testing and
Resetting Procedure” in the MAIN-
TENANCE section of this manual.

3. Faulty connections to auxiliary

receptacles. Check connections.

4. Faulty PC board or welder alterna-

tor.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.

Advertising