INSTALLATION
AUTOPRO™ (140/180 MODELS)
OPERA
T
OR’S MANUAL
TECHNICAL SPECIFICATIONS 180 Amp unit (K3293-1)
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Standard Voltage/Frequency
Input Current
230 V 60 Hz
20 Amps @ rated output
208 V 60 Hz
20 Amps @ rated output
Voltage/Duty Cycle
Current
Voltage at Rated Amperes
230 V 30%
130 Amps
20
208 V 30%
130 Amps
17.6
Welding Current Range
Open Circuit Voltage
Wire Speed Range
30-180 Amps
34 V
50 - 500 in/min.
(1.3 - 12.7 m/min.)
Input Voltage/Frequency Fuse or Breaker Size
1
Input Amps Minimum Input Cable
230/208 V 60 Hz 40 Amp Super Lag
20 14 AWG
RECOMMENDED INPUT CABLE AND FUSE SIzES
Height
Width
Depth
Weight
13.7 in
10.4 in
18.2 in
56 Ibs
347 mm
264 mm
462 mm
25.4 kg
PHYSICAL DIMENSIONS
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.
TECHNICAL SPECIFICATIONS 140 Amp unit (K3292-1)
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Standard Voltage/Frequency
Input Current
120 V / 60 Hz
20 Amps @ rated output
Duty Cycle
Current
Voltage at Rated Amperes
20% Duty Cycle
90 Amps
19.5
Welding Current Range
Open Circuit Voltage
Wire Speed Range
30-140 Amps
33 V
50 - 500 in/min.
(1.3 - 12.7 m/min.)
Input Voltage/Frequency Fuse or Breaker Size
1,2
Input Amps
Power Cord Extension Cord
120 V 60 Hz 20 Amp
20
15 Amp, 125 V, 3 Conductor # 12 AWG
Three Prong Plug (4mm
2
) or Larger
(NEMA Type 5-15P) up to 50 ft.(15.2m)
RECOMMENDED INPUT CABLE AND FUSE SIzES
Height
Width
Depth
Weight
13.7 in
10.4 in
18.2 in
50.0 Ibs
347 mm
264 mm
462 mm
22.7 kg
PHYSICAL DIMENSIONS
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.
2
Requirements For Maximum Output
In order to utilize the maximum output capability of the machine, a branch
circuit capable of 25 amps at 120 volts, 60 Hertz is required.