err# Status

Fault message

possible Cause

Display

1

t

power stage overTemp

overload, fan malfunction, power stage failure

2

o

overVoltage

excessive decel rate*

3

p

overCurrent

power stage surge current*

4.0

ro

external feedback fault

Feedback signal through C8 not correctly detected

4.1

r1

Resolver line break

break in resolver feedback detected

4.2

r2

RDC error

Fault in resolver-to-digital converted detected

4.3

r3

Sinc encoder init fail

Sinc encoder card has not initialized properly

4.4

r4

A/b line break

break in encoder A/b input lines detected

4.5

r5

Index line break

break in encoder index line

4.6

r6

Illegal halls

Illegal hall combination detected

4.7

r7

C/D line break

break in sinc encoder C/D line detected

4.8

r8

A/b out of range

Sinc encoder A/b level out of range

4.9

r9

burst pulse overflow

Sinc encoder fault

5

u

Under voltage

bus voltage is too low

6

H

motor over temperature

motor overload caused overheating

7.1

A1

positive analog supply fail

Failure in +12V supply

7.2

A2

negative analog supply fail

Failure in -12V supply

8

J

overSpeed

Velocity ≥ VoSpD

8.1

J1

overSpeed

Velocity ≥ 1.8 x VlIm

9

e

eepRom failure

Faulty eepRom

10

e

eepRom checksum fail

eepRom checksum invalid on power up*

12

F

Foldback

System in Foldback mode

14.1

d5

positive over travel fault

pFb exceeded pmAX with plIm=1

14.2

d6

negative over travel fault

pFb exceeded pmIn with plIm=1

15.1

d1

numeric position deviation

Internal Fault

15.2

d2

excessive position deviation

pe > pemAX

16

c

Communication interface

A communication fault has occurred

*These faults can only be cleared by cycling power

“main Selection menu” is displayed.

. reset.Job.parameters

. to.deFault.Value

. F1=reset.Values

. F4=return-don’t.reset

It is very important that the opera-

tor make a hard copy of the jobs

on a sheet of paper so there is a

permanent record.

FATAl FAUlT ERROR CODES

7.3.1.Fatal.Fault.error.codes

Advertising