Reset parameters, Reset job parameters – Rapid-Air SERVO FEED: 100C, 100D series User Manual
Page 11

The reset job parameters routing
should be used with special caution.
We incorporated it as a user function
for two reasons.
The first reason is if a problem caused
the displayed parameters to be
garbled because of a program glitch,
then by resetting the job parameters
the problem could be cleared.
The second reason is if there were a
number of different jobs in memory
that were no longer required, then by
resetting the job parameters, all the
job numbers would be reset to their
default values, which includes putting
all zeros in the feed length and strokes
per minute area of the program.
RESET PARAmETERS
Reset Job Parameters
CAUTION!!
CAUTION!!
CAUTION!!
Keep a hard copy record of
program numbers and data
associated with them for reference
if needed. If this function is used
in a way other than what it was
designed for then all previous
data is lost and cannot be
recovered.
To enter this function, turn off the
program by depressing the master
stop button. Turn on the program
again and push and hold the “clear
entry” key, once the program has
started the following screen will
be displayed.
**DEFAULT VALUE SETUP
PRESS F1 TO RESET TO
DEFAULT VALUES, PRESS
F4 TO IGNORE CHANGES
**Once F1 has been pressed then all
data that had been entered will be reset.
PROGRAM NUMBER DISPLAY
Each servo unit that is shipped has a
program number assigned to it. If a
problem occurs and cannot be solved
by reloading the program then you
will be asked the program number
associated with this servo. To view the
program number, press and hold the
“back space” key during the power up
sequence. The program number will be
displayed for about 30 seconds. Please
find and write down the program
number in case it is needed in the future.