Reset parameters, Reset job parameters – Rapid-Air SERVO FEED: 100C, 100D series User Manual

Page 11

Advertising
background image



The reset job parameters routing

should be used with special caution.

We incorporated it as a user function

for two reasons.

The first reason is if a problem caused

the displayed parameters to be

garbled because of a program glitch,

then by resetting the job parameters

the problem could be cleared.

The second reason is if there were a

number of different jobs in memory

that were no longer required, then by

resetting the job parameters, all the

job numbers would be reset to their

default values, which includes putting

all zeros in the feed length and strokes

per minute area of the program.

RESET PARAmETERS

Reset Job Parameters

CAUTION!!

CAUTION!!

CAUTION!!

Keep a hard copy record of

program numbers and data

associated with them for reference

if needed. If this function is used

in a way other than what it was

designed for then all previous

data is lost and cannot be

recovered.

To enter this function, turn off the

program by depressing the master

stop button. Turn on the program

again and push and hold the “clear

entry” key, once the program has

started the following screen will

be displayed.

**DEFAULT VALUE SETUP

PRESS F1 TO RESET TO

DEFAULT VALUES, PRESS

F4 TO IGNORE CHANGES

**Once F1 has been pressed then all

data that had been entered will be reset.
PROGRAM NUMBER DISPLAY

Each servo unit that is shipped has a

program number assigned to it. If a

problem occurs and cannot be solved

by reloading the program then you

will be asked the program number

associated with this servo. To view the

program number, press and hold the

“back space” key during the power up

sequence. The program number will be

displayed for about 30 seconds. Please

find and write down the program

number in case it is needed in the future.

Advertising