Now that your servo feed unit has

been mounted and the cables have

been attached, you can proceed with

testing the unit. The first step is to

turn on the main disconnect switch

on the electrical enclosure. Next, at

the operator’s console, turn on the

on-off switch. The button should

illuminate to indicate that there is

power to the system.

The drive performs an initiate

sequence to check it’s internal

program. At this time the display

should show the Rapid-Air screen

for 5 seconds before starting the

main setup program. If you are

comfortable with programming a

job then continue; if not, please

refer to the “Programming

Procedure” located in this manual.

Follow the programming sequence

for the operators terminal to input

parameters into job storage. Your

servo feed has been fully tested

before it was shipped to your facility

PRETEST wRITE UP

Pretest For Servo Feed And Press Without Material

and this procedure is merely a test to

insure that all functions are

still functional and the cables are

properly seated.

Once you have programmed the

required parameters, select the

manual mode of operation. If you

are using air, check that the main

air is at least 80 PSI. Open and close

the feed rolls electrically and or

manually. Visually inspect that the

rolls open and close as you press the

appropriate keys on the keypad or

when using the manual levers.

Select the “inch” function (F2 on

keypad) on the manual mode screen.

Visually check that the rolls rotate

both forward and reverse with the

corresponding key. The speed is

preset to creep the rolls at a slow

speed for manual positioning of

the material.

CAUTION: Do not attempt to

place your fingers or any foreign

material into the rolls. Injury to the

operator or damage to the servo

rolls could result.

After you have verified that the rolls

and air logic are operational, you

can experiment with the single

cycle moves. The procedure is

outlined in the programming section

of this manual.

Now you can cycle the press and

watch the rolls to verify that the

signal from the press window switch

signal is functional and actuating

at the proper time.

After all the checks have been made

and you feel comfortable with the

programming of the servo controller,

place the servo in automatic mode.

Now cycle the press in either the

inch, single stroke or continous run.

The servo feed should react upon

the closure of the press window

and signal and simulate a feed

progression of material.