Connecting the dc power cord – Proface GP4600R - 12.1 Standard HMIs with Rear Mounting Options" User Manual

Page 26

Advertising
background image

27

Wiring

En

g

lish

2. Connecting the DC Power Cord

Field wiring terminal marking for wire type (75

°C (167 °F) Copper conductors

only)

*1 If the conductor’s end (individual) wires are not twisted correctly, the end

wires may either short against each other or against an electrode.

3

Remove screws from the L, N, and FG (functional ground)
terminals. Attach the ring terminals and reinsert the screws.
Check each wire to make sure the connections are correct.

Note :

• Terminal Block: 1.4 N•m (12.4 lb•in.)
• FG (functional ground) Terminal: 1.4 N•m (12.4 lb•in.)

4

Close the terminal strip’s clear plastic cover.

Power Cord Diameter

0.75 to 2.5 mm

2

(18-13 AWG)

Conductor type

Simple or Stranded Wire

*1

Conductor length

)*

mm
in.

10
0.39

Advertising