Proface AGP3500 - 10.4 DIO HMI" User Manual

Page 11

Advertising
background image

11

For GP units with emergency switches, the enabled emergency switch activates the contact
output. To reset the emergency stop status (lock status), pull the button forward, or turn the
button in the direction indicated by arrow.

When the emergency switch is pressed, ON/OFF status of the EMG0 to EMG2 signals are as
follows:

( ) indicates contact status.

• These signal lines must be disconnected (NC) when a GP unit without an emergency switch is

used.

„ Key Switch Output Interface

• Turning OFF GP unit with the key switch

Emergency Stop Reset

Emergency Stop

EMG0

0 (OFF)

1 (ON)

EMG1

1 (ON)

0 (OFF)

EMG2

1 (ON)

0 (OFF)

Cable Color/

Marking Color,

Number

Signal Name

Meaning

Orange/None

KEY_NC

Key Switch b-contact (normally closed)
Rating: DC24V, 300 mA

Orange/Black 1

KEY_NO

Key Switch a-contact (normally open)
Rating: DC24V, 300 mA

EMG2A

EMG1A

EMG0A

EMG0B

EMG1B

EMG2B

DC24V

GP

OFF

ON

KEY_NO

KEY_NC

GP3000H Cable

Advertising