PS-4000B Series User Manual

98

Mounting Instructions

By integrating the charging circuit in the PS-B housing, installation is reduced to
merely attaching the connection cable to the UPS battery unit mounted next to the
PS-B.

Due to the construction of these batteries, you can store and operate the UPS
battery unit in any position.

For mounting the UPS battery unit, use the following figure as the drilling template:

Materials
Cable Shielding
Color

Thermoplastic PVC-based material
Window gray (similar to RAL 7040)

Peak Operating Voltage

12 Vdc

Testing AC Voltage
Wire/wire

1500 V

Operating Voltage

Max. 300 V

Current Load

10 A at + 20

°C (10 A at + 68 °F)