3 wiring precautions, 1 connecting the power cord, 3 wiring precautions -18 – Proface APL3000B - Node Box PC User Manual

Page 61: 1 connecting the power cord -18, 18 3.3 wiring precautions

Advertising
background image

PS-3710A Series Hardware Manual

3-18

3.3

Wiring Precautions

This section describes the procedures and precautions for wiring power cords.

3.3.1

Connecting the Power Cord

Power Cord Specifications

To avoid an electric shock, prior to connecting the PS-A unit’s power cord terminals to the

power terminal block, confirm that the PS-A unit’s power supply is completely turned OFF,

via a breaker, or similar unit.

Supplying a power voltage other than that specified will damage the power source and the

PS-A unit.

When the FG terminal is connected, be sure the wire is grounded.

• When the FG terminal is connected, be sure the wire is grounded. Not grounding

the PS-A unit will result in excess noise and vibration.

• The SG and FG terminals are connected internally in the PS-A unit.

When connecting the SG wire to another device, be sure that the design of the

system/connection does not produce a shorting loop.

The PS-A units is designed to use AC100V to AC240V input. Supplying a power voltage

other than that specified will damage the power source and the PS-A unit.

Power Cord Diameter

0.75 to 2.5mm

2

(18 to 12 AWG)

Conductor Type

Simple or Stranded Wire

*1

*1

If the Conductor’s end (individual) wires are not twisted correctly, the end

wires may either short against each other, or against an electrode.

Conductor Length

• Use copper conductors only.

10mm[0.39in.]

Advertising