A . 1 8

A p p e n d i x

W a t l o w S e r i e s 9 3

Appendix

[`LOC] Lock
[``In] Input
[`dEC] Decimal*
[`C_F] Celsius - Fahrenheit*
[``rL] Range Low
[``rH] Range High
[`Ot1] Output 1
[`HSC] Hysteresis Control
[`Ot2] Output 2
[`HSA] Hysteresis Alarm*
[`LAT] Latching*
[`SIL] Silencing*
[`rtd] RTD*
[`rP`] Ramping
[`rT`] Rate*
[`P`L] Power Limiting*
[`dSP] Display

* Parameter may not always appear.

Setup Menu

[``93] Control Set Point
[`Pb1] Proportional Band 1
[`rE1] Reset 1*
[`It1] Integral 1*
[`rA1] Rate 1*
[`dE1] Derivative 1*
[`Ct1] Cycle Time 1*
[`ALO] Alarm Low*
[`AHI] Alarm High*
[`Pb2] Proportional Band 2*
[`rE2] Reset 2*
[`It2] Integral 2*
[`rA2] Rate 2*
[`dE2] Derivative 2*
[`Ct2] Cycle Time 2*
[`CAL] Calibration Offset
[`AUt] Autotune

Operation Menu

* Parameter may not always appear.

Parameter

Value

Range

Factory Default

Appears If:

[`LOC]

0 - 4

0

[``In]

[```J], [```H], [```t], [```n],

[```J]

DIP switch-selectable.

[```S][`rtd], [`r†d], [`0-5], [`420]

[`dEC]

0, 0.0, 0.00

0

[``In] is set to [`0-5]

or

[`420]

[`C_F]

[```C] or [```F]

Dependent on

[`dFL]

[``In] is set to [```J],
[```H], [```t], [```n],

[```S], [`rtd], or [`r†d]

[``rL]

[``rL] to [``rh]

Input dependent.

[``rh]

[``rh] to [``rL]

Input dependent.

[`Ot1]

[``ht] or [``CL]

[``ht]

[`HSC]

1 to 55, 0.1 to 5.5, 0.01 to 0.55°C

2, 0.2, 0.02°C

1 to 99, 0.1 to 9.9, 0.01 to 0.99°F

3, 0.3, 0.03°F

[`Ot2]

[`Con] Control

[`Con]

[`PrA] Process Alarm
[``Pr] Process with no alarm message
[`dEA] Deviation alarm
[``dE] Deviation with no alarm message
[``no] None

[`HSA]

1 to 5555, 0.1 to 555.5, 0.01 to 55.55°C

2, 0.2, 0.02°C

[`Ot2] is not set to [`Con]

1 to 9999, 0.1 to 999.9, 0.01 to 99.99oF

3, 0.3, 0.03°F

or

[``no]

[`LAt]

[`LAt] or [`nLA]

[`nLA]

[`Ot2] is not set to [`Con]

or

[``no]

[`SIL]

[``On] or [`OFF]

[`OFF]

[`Ot2] is set to [`dEA] or
[``dE]

[`rtd]

[`JIS] or [`din]

[`din]

[``In] is set to [`rtd] or
[`r†d]

[`rP`]

[`Str] is set to Ramping on power up

[`OFF]

[``on] is set to Ramping to set point always
[`OFF] is set to None

[`rt`]

0 to 9999

100°/hr

[``rP] is not set to [`OFF]

[`P`L]

0 to 100

100

[`dsP]

[`nor] normal

[`nor]

[`SEt] Set Point (lower only)
[`Pro] Process (upper only)

Parameter

Value

Range

Factory Default

[`Pb1]

If

[`dFL] is set to [``US]:

0 to 555°C/0 to 999°F/0 to 999 Units

25°F

0 to 55.5°C/0 to 99.9°F/0 to 99.9 Units

2.5°F

0 is set to on-off control.

[`HSC] is set to switch differential

If

[`dFL] is set to [``SI]:

0.0 to 999.9% of span

3%

[`rE1]

0.00 to 9.99 repeats/minute

0.00 repeats/minute

0.00 = No Reset. Won't appear if

[`Pb1] is set to 0

or

[`dFL] is set to [``SI].

[`It1]

0.0 to 99.9 minutes/rpt. 0.00 = No Integral.

00.0 minutes/repeat

Won't appear if

[`Pb1] is set to 0 or [`dFL] is set to [``US].

[`rA1]

0.00 to 9.99 minutes

0.00 minutes

0.00 = No Rate. Will not appear if

[`Pb1] is set to 0

or

[`dFL] is set to [``SI].

[`dE1]

0.00 to 9.99 minutes. 0.00 = No Derivative.

0.00 minutes

Won't appear if

[`Pb1] is set to 0 or [`dFL] is set to [``US].

[`Ct1]

0.1 to 999.9

5.0 seconds

Won't appear if

[`Pb1] = 0, or [`420].

[`Pb2]

Same as

[`Pb1]. [`Pb2] lower limit = 1, 0.1, 0.01

[`rE2]

Same range as

[`rE1].

[`It2]

Same range as

[`It1].

[`rA2]

Same range as

[`rA1].

[`dE2]

Same range as

[`dE1].

[`Ct2]

Same range as

[`Ct1].

[`ALO]

Deviation

[``dE]

-999 to 0

-999

Process

[``Pr]

[``rL] to [`AHI]

[``rL]

Will not appear if

[`Ot2] is set to [``no] or [`Con].

[`AHI]

Deviation

[``dE]

0 to 999

999

Process

[``Pr]

[`ALO] to [``rH]

[``rH]

Will not appear if

[`Ot2] is set to [``no] or [`Con].

[`CAL]

±100°C/±180°F/±180 Units

0

[`AUt]

0 to 3

0

Setup Menu

Operation Menu

93

Enter the Setup Menu by
pressing the ¿Up-arrow and
¯Down-arrow keys simulta-
neously for three seconds. The
lower display shows the
[`LOC] Lock parameter, and
the upper display shows its
current level. All keys are
inactive until you release both
keys. You can reach the Lock
parameter from anywhere.
Use the ‰Advance key to
move through the menus and
the ¿Up-arrow and ¯Down-
arrow keys to select data. You
will not see all parameters in
this menu, depending on the
controller's configuration and
model number.

Note:
Do not enter any values here;
make photocopies instead.

Advertising