Yokogawa EJA530E User Manual

Page 44

Advertising
background image

<9. General Specifications>

9-4

IM 01C25F01-01E

Communication Requirements “◊”

(Safety approvals may affect electrical

requirements.)

BRAIN

Communication Distance

Up to 2 km (1.25 miles) when using CEV

polyethylene-insulated PVC-sheathed cables.

Communication distance varies depending on

type of cable used.
Load Capacitance

0.22 μF or less
Load Inductance

3.3 mH or less
Input Impedance of communicating device

10 kΩ or more at 2.4 kHz.

HART

Communication Distance

Up to 1.5 km (1 mile) when using multiple

twisted pair cables. Communication distance

varies depending on type of cable used.
Use the following formula to determine cable

length for specific applications:

L=

65 × 10

6

(R × C)

(C

f

+ 10,000)

C

Where:

L = length in meters or feet

R = resistance in Ω (including barrier

resistance)

C = cable capacitance in pF/m or pF/ft

C

f

= maximum shunt capacitance of receiving

devices in pF/m or pF/ft

EMC Conformity Standards

,

EN61326-1 Class A, Table2 (For use in industrial

locations)

EN61326-2-3

Physical Specifications

Wetted Parts Materials

Diaphragm, Process Connector

Refer to “Model and Suffix Code.”

Non-wetted Parts Materials

Housing

Low copper cast aluminum alloy with

polyurethane paint or ASTM CF-8M stainless

steel
Degrees of Protection

IP66/IP67, NEMA TYPE 4X
Pipe

Polypropylene
Cover O-rings

Buna-N, fluoro-rubber (option)
Nameplate and tag

316SST (including /N4 wired tag)
Fill Fluid

Silicone, Fluorinated oil (option)

Weight

Capsule A, B and C: 1. 2kg (2.6 lb)*

Capsule D: 1.4 kg (3.1 lb)*

*: Without integral indicator and mounting bracket.

Add 1.5 kg (3.3lb) for Amplifier housing code 2.

Connections

Refer to “Model and Suffix Code.”